## Abstract The analysis by gas chromatography coupled with mass spectrometry (GC/MS) of 40 different congeners of polybrominated diphenyl ethers (PBDEs) containing 1–7 bromine atoms is described. Two different MS approaches were used, negative chemical ionization (NCI‐MS) and electron ionization (
Gas chromatography and mass spectrometry of methoxylated polybrominated diphenyl ethers (MeO-PBDEs)
✍ Scribed by Maria Athanasiadou; Göran Marsh; Ioannis Athanassiadis; Lillemor Asplund; Åke Bergman
- Publisher
- John Wiley and Sons
- Year
- 2006
- Tongue
- English
- Weight
- 286 KB
- Volume
- 41
- Category
- Article
- ISSN
- 1076-5174
- DOI
- 10.1002/jms.1035
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Twenty‐six methoxylated polybrominated diphenyl ethers (MeO‐PBDEs) were characterized by gas chromatography (GC) on four different GC columns with different lengths and polarities, as well as by mass spectrometry using three ionization techniques, electron ionization (EI), electron capture negative ionization (ECNI) and positive ion chemical ionization (PICI). MeO‐PBDE congeners with similar retention times on a nonpolar GC column were separated when analyzed on a polar GC column. EI can be used to determine the position of the methoxy substituent (ortho, meta or para) relative to the diphenyl ether oxygen in the MeO‐PBDEs. The PICI ionization technique is shown to be valuable to generate structural information of the MeO‐PBDEs, i.e. the degree of bromination on both the methoxy‐substituted ring and the entirely brominated phenyl ring can be obtained. This structure information can also be achieved for certain MeO‐PBDEs with the methoxy group in ortho position to the diphenyl ether bond in ECNI mode. Like other brominated compounds ECNI is preferable when analyzing environmental samples for quantification of MeO‐PBDEs because of the formation of bromide ions, which enables low detection limits. Copyright © 2006 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
## Abstract An effective multi‐residue pretreatment technique, solid‐phase extraction (SPE) combined with dispersive liquid–liquid microextraction (DLLME), was proposed for the trace analysis of 14 polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) in milk samples using gas
## Abstract Gas chromatography coupled to quadrupole ion storage mass spectrometry (QISTMS) operating in the non‐resonant mode is presented as an innovative approach for the analysis of selected polybrominated diphenyl ethers (PBDEs). Although reductions in complexity and time needed for optimizati