## Abstract The enantiomers of phenoxypropionic acid type herbicides have been resolved by capillary gas chromatography employing modified cyclodextrins as chiral stationary phases. Excellent separations were obtained with columns containing a 1:1 mixture of per‐__O__‐pentylated and per‐__O__‐methy
Gas chromatographic enantiomer separation of agrochemicals and polychlorinated biphenyls (PCBs) using modified cyclodextrins
✍ Scribed by Hardt, Ingo H. ;Wolf, Christian ;Gehrcke, Bärbel ;Hochmuth, Detlev H. ;Pfaffenberger, Bernd ;Hühnerfuss, Heinrich ;König, Wilfried A.
- Publisher
- John Wiley and Sons
- Year
- 1994
- Tongue
- English
- Weight
- 512 KB
- Volume
- 17
- Category
- Article
- ISSN
- 0935-6304
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The enantiomers of the polychlorinated polycyclic xenobiotics heptachlor, cis‐ and trans‐chlordane, cis‐ and trans‐heptachlorepoxide, oxychlordane, and bromocyclen have been resolved by gas chromatography with selectively substituted cyclodextrins. The order of elution of these compounds and of α‐hexachlorocyclohexane (α‐HCH) was determined by comparison with enantiomerically enriched reference compounds obtained by preparative enantioselective gas chromatography.
A separation of the eight stereoisomers of the pyrethroid insecticide allethrin into seven peaks was achieved. Both trans‐diastereomers were separated into their enantiomers and the order of elution could be determined by comparison with commercially available (S)‐bioallethrin and trans‐bioallethrin. Also one cis‐diastereomer was separated, wheras the other cis‐isomer could not be resolved. In addition 15 out of 19 stable atropisomeric polychlorinated biphenyls with 5, 6 and 7 chlorine substituents, some chiral organophosphorus pesticides, including acephate and malaoxon and the herbicide bromoacil were separated.
📜 SIMILAR VOLUMES
## Abstract Selectively alkylated cyclodextrins have been used to resolve the enantiomers of 2,2′ alkylated biphenyls. The configurational stability of 2,2′‐dimethyl and 2,2′‐diethyl biphenyls is insufficient for gas chromatographic separation even at ambient temperature. 2‐Isopropyl‐2′‐__t__‐butyl
## Abstract The wide range of application of 2,6‐di‐__O__‐methyl‐3‐__O__‐pentyl‐β‐and __y__‐cyclodextrins is demonstrated by the resolution of the enantiomers of the methyl esters of chiral carboxylic acids: α and β hydroxy acids with up to 18 carbon atoms, hydroxy di‐ and tricarboxylic acids, and
## Abstract The technical PCB mixtures Aroclol and Clophen have been analyzed by packed column supercritical fluid chromatography using negative temperature programming. The chromatographic method was successfully applied to the analysis of PCBs, polycyclic aromatic hydrocarbons, and polychlorinate