## Abstract ## Purpose To combine parallel imaging with 3D single‐shot acquisition (echo volumar imaging, EVI) in order to acquire high temporal resolution volumar functional MRI (fMRI) data. ## Materials and Methods An improved EVI sequence was associated with parallel acquisition and field of
Functional MRI using regularized parallel imaging acquisition
✍ Scribed by Fa-Hsuan Lin; Teng-Yi Huang; Nan-Kuei Chen; Fu-Nien Wang; Steven M. Stufflebeam; John W. Belliveau; Lawrence L. Wald; Kenneth K. Kwong
- Publisher
- John Wiley and Sons
- Year
- 2005
- Tongue
- English
- Weight
- 889 KB
- Volume
- 54
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Parallel MRI techniques reconstruct full‐FOV images from undersampled __k‐__space data by using the uncorrelated information from RF array coil elements. One disadvantage of parallel MRI is that the image signal‐to‐noise ratio (SNR) is degraded because of the reduced data samples and the spatially correlated nature of multiple RF receivers. Regularization has been proposed to mitigate the SNR loss originating due to the latter reason. Since it is necessary to utilize static prior to regularization, the dynamic contrast‐to‐noise ratio (CNR) in parallel MRI will be affected. In this paper we investigate the CNR of regularized sensitivity encoding (SENSE) acquisitions. We propose to implement regularized parallel MRI acquisitions in functional MRI (fMRI) experiments by incorporating the prior from combined segmented echo‐planar imaging (EPI) acquisition into SENSE reconstructions. We investigated the impact of regularization on the CNR by performing parametric simulations at various BOLD contrasts, acceleration rates, and sizes of the active brain areas. As quantified by receiver operating characteristic (ROC) analysis, the simulations suggest that the detection power of SENSE fMRI can be improved by regularized reconstructions, compared to unregularized reconstructions. Human motor and visual fMRI data acquired at different field strengths and array coils also demonstrate that regularized SENSE improves the detection of functionally active brain regions. Magn Reson Med 54:343–353, 2005. © 2005 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract Increased spatiotemporal resolution in MRI can be achieved by the use of parallel acquisition strategies, which simultaneously sample reduced __k__‐space data using the information from multiple receivers to reconstruct full‐FOV images. The price for the increased spatiotemporal resolut
## Abstract A parallel image acquisition system has been developed to solve the dynamic range problem in MRI. The parallel receiver system was tested using 3D large matrix spin echo and gradient echo images. The dynamic range of the receiver system was extended to about 80 dB, which was sufficient
## Abstract A new acquisition technique for rapid, whole‐brain functional MRI is presented. In this technique, several slices are simultaneously acquired using rosette __k‐space__ trajectories and a gradient‐induced frequency modulation. This modulation together with the spectral properties of the
## Abstract The noninvasive assessment of lung function using imaging is increasingly of interest for the study of lung diseases, including chronic obstructive pulmonary disease (COPD) and asthma. Hyperpolarized gas MRI (HP MRI) has demonstrated the ability to detect changes in ventilation, perfusi