✦ Synopsis


Abstract

The legally defensible identification of the narcotic, analgesic buprenorphine, in biological specimen requires considerable sensitivity due to its low therapeutic dosages and corresponding target concentrations. Application of liquid chromatography‐electrospray ionisation‐mass spectrometry, which became the default method for buprenorphine detection, is impeded by the disadvantageous fragmentation of the stable precursor ion producing unspecific product ions of comparatively low abundance.

A chemical modification to form the N‐methylpyridinium ether derivative of buprenorphine is presented to improve the selectivity and sensitivity of its detection by liquid chromatography‐mass spectrometry (LC‐MS).

The reaction of buprenorphine with 2‐fluoro‐1‐methyl‐pyridinium‐p‐toluene‐sulfonate and triethylamine as catalyst was accomplished in acetonitrile at an ambient temperature yielding a chemically stable derivative. Fragmentation of the permanently charged precursor ion (m/z = 559) leads to the formation of diagnostic and abundant fragments (e.g. m/z = 443 and 450) representing all parts of the molecule.

The application of the technique to the identification of buprenorphine in hair samples demonstrates a high specificity, availability of sufficient qualifier ions and a significant (∼8‐fold) improvement of detection limits with respect to comparable experiments based on underivatised buprenorphine. Copyright © 2008 John Wiley & Sons, Ltd.


📜 SIMILAR VOLUMES


Improved detection of multi-phosphorylat
✍ Jeongkwon Kim; David G. Camp II; Richard D. Smith 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 178 KB

## Abstract In contrast to lower phosphorylation states (e.g. the tryptic monophosphopeptide FQpSEEQQQTEDELQDK from bovine β‐casein), the specific detection of multi‐phosphorylated peptides (e.g. the tetraphosphopeptide RELEELNVPGEIVEpSLpSpSpSEESITR from tryptic digestion of bovine β‐casein) has of

Charge-exchange reactions with water in
✍ S. K. Huang; D. H. Klein; M. McLoughlin 📂 Article 📅 1989 🏛 John Wiley and Sons 🌐 English ⚖ 370 KB 👁 1 views

Peduorocarbons (PFCs) can be detected by thermospray liquid chromatography/mass spectrometry (LC/MS) only when the system is operated in the negative ion mode with filament on and some water entering the thermospray source. A new mechanism for PFC ionization is proposed, based on studies of LC/MS de

Evaluation of different scan methods for
✍ Oscar J. Pozo; Rosa Ventura; Núria Monfort; Jordi Segura; Frans T. Delbeke 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 367 KB

## Abstract Different approaches for the non‐target detection of corticosteroids in urine have been evaluated. As a result of previous studies about the ionization (positive/negative) and fragmentation of corticosteroids, several methods based on both precursor ion (PI) and neutral loss (NL) scans

Mass spectrometry in the study of anthoc
✍ Pierluca Mazzuca; Pasquale Ferranti; Gianluca Picariello; Lina Chianese; Frances 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 177 KB