✦ Synopsis


Abstract

Different approaches for the non‐target detection of corticosteroids in urine have been evaluated. As a result of previous studies about the ionization (positive/negative) and fragmentation of corticosteroids, several methods based on both precursor ion (PI) and neutral loss (NL) scans are proposed. The applicability of these methods was checked by the injection of a standard solution containing 19 model compounds. Five of the studied methods (NL of 76 Da; PI of 77, 91 and 105; PI of 237; PI of 121, 147 and 171; and NL of 38 Da) exhibited satisfactory results at the concentration level checked (corresponding to 20 ng/ml in sample). Some other methods in negative ionization mode such as the NL of 104 Da were found to lack sufficient sensitivity. Some of the applied methods were found to be specific for a concrete structure (NL of 38 Da for fluorine containing corticosteroids) while others showed a wide range applicability (PI of 77, 91 and 105 showed response in all model compounds). Interference by endogenous compounds was also tested by the analysis of negative urines and urines spiked with different corticosteroids. The suitability of these methods for the detection of corticosteroid metabolites was checked by the analysis of urine samples collected after the administration of methylprednisolone and triamcinolone. A combination of the reported methods seems to be the approach of choice in order to have a global overview about the excreted corticosteroid metabolites. Copyright © 2009 John Wiley & Sons, Ltd.


📜 SIMILAR VOLUMES


Elucidation of urinary metabolites of fl
✍ Oscar J. Pozo; Wim Van Thuyne; Koen Deventer; Peter Van Eenoo; Frans T. Delbeke 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 340 KB

## Abstract The suitability of liquid chromatography tandem mass spectrometry (LC‐MS/MS) and gas chromatography mass spectrometry (GC‐MS) for the elucidation of fluoxymesterone metabolism has been evaluated. Electrospray ionization (ESI) and collision induced dissociation (CID) fragmentation in LC‐

Collision-induced dissociation of cortic
✍ Jean-Philippe Antignac; Bruno Le Bizec; Fabrice Monteau; Frédéric Poulain; Franç 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 114 KB 👁 2 views

A screening method based on liquid chromatography/electrospray tandem mass spectrometry was developed in order to control the illegal use of corticosteroids as growth promoters in cattle. The objective was the detection of low residue levels of corticosteroids or metabolites in biological matrices.

Rapid characterization of urinary metabo
✍ K. Kato; S. Jingu; N. Ogawa; S. Higuchi 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 108 KB 👁 2 views

The metabolic products of pibutidine hydrochloride, a new H 2 -receptor antagonist, in human urine after oral administration of 40 mg/man were characterized by high-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS) with electrospray ionization (ESI). Two-stage collision-induced d

Sensitive liquid chromatography tandem m
✍ Ramakrishna Nirogi; Gopinadh Bhyrapuneni; Vishwottam Kandikere; Koteshwara Mudig 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 515 KB

## Abstract A sensitive high‐performance liquid chromatography–tandem mass spectrometry method was developed and validated for the quantification of quetiapine in rat plasma. Following liquid–liquid extraction, the analyte was separated using a gradient mobile phase on a reverse‐phase column and an