Fluoroquinolone antibiotics in environmental waters: Sample preparation and determination
โ Scribed by Andrea Speltini; Michela Sturini; Federica Maraschi; Antonella Profumo
- Publisher
- John Wiley and Sons
- Year
- 2010
- Tongue
- English
- Weight
- 229 KB
- Volume
- 33
- Category
- Article
- ISSN
- 1615-9306
No coin nor oath required. For personal study only.
โฆ Synopsis
Abstract
The aim of this review is to provide a general overview on the analytical methods proposed in the last decade for trace fluoroquinolone (FQ) determination in environmental waters. A large number of studies have been developed on this topic in reason of the importance of their monitoring in the studies of environmental mobility and potential degradation pathways. Every step of the analysis has been carefully considered, with a particular attention to sample preparation, in relationship with the problems involved in the analysis of real matrices. The different strategies to minimise interference from organic matter and to achieve optimal sensitivity, especially important in those samples with lower FQ concentrations, were also highlighted. Results and progress in this field have been described and critically commented. Moreover, a worldwide overview on the presence of FQs in the environmental waters has been reported.
๐ SIMILAR VOLUMES
## Abstract A novel LCโfluorescence detection method based on the use of a monolithic column for the determination of norfloxacin, ciprofloxacin, and enrofloxacin antibiotic residues in environmental waters was developed. Fluoroquinolones (FQs) were isocratically eluted using a mobile phase consist
## Abstract Three different SPE sorbents (weak cation exchange, mixed cation exchange, and hydrophobicโlipophilic balance polymers) were compared in terms of recovery, precision, and the effect of matrix components on analyte response for the determination of fluoroquinolones antibiotics. The influ
## Abstract A high resolution liquid chromatographic method is described for determination of low molecular weight (LMW) aliphatic amines in environmental waters. The analytes after isolation are derivatized by fluram and separated with isocratic elution on octyl (C~8~) column, followed by fluorime
This work deals with a simple, rapid, and efficacious design for the measurement of 137Cs in seawater . An adsorption filter is fabricated by coating copper(II) hexacyanoferrate(II) (CuCF) onto a densely twilled nylon cloth . The CuCF-nylon cloth filter is cut into round pieces and screwed into a po