๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Flow injection analysis of myoglobin and hemoglobin at toluidine blue chemically modified electrode

โœ Scribed by Jianxun Zhou; Erkang Wang


Publisher
John Wiley and Sons
Year
1991
Tongue
English
Weight
427 KB
Volume
3
Category
Article
ISSN
1040-0397

No coin nor oath required. For personal study only.

โœฆ Synopsis


Abstract

Electrodeposition of the phenothiazine mediator titrant toluidine blue onto a glassy carbon substrate at an appropriate potential was used to construct a toluidine blue chemically modified electrode (CME) exhibiting electrocatalytic reduction for myoglobin and hemoglobin. The CME catalyzed the hemoprotein electroreduction at the reduction potential of the mediator molecule. When the CME as used as a detector for flow injection analysis at a constant applied potential of โˆ’0.30 V vs. a saturated calomel electrode, it gave detection limits of 20 and 50 ng (1.2 and 0.78 pmol) injected myoglobin and hemoglobin, respectively, with a dynamic linear concentration range over 2 orders of magnitude. After a brief equilibration period, the CME retained nearly 90% of its initial myoglobin response over 8 hours of continuous exposure to the flowโ€through system.


๐Ÿ“œ SIMILAR VOLUMES


Electrocatalysis and Flow-Injection Anal
โœ Jianhong Pei; Xiao-yuan Li ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 265 KB ๐Ÿ‘ 3 views

Cyclic voltammetry was used to investigate the electrochemical behavior of peroxides, both hydrogen and organic, on the CuPtCl 6 aGC modiยฎed electrode which displayed great electrocatalytic activity in the redox of peroxide. The results show that the electrochemical processes of peroxide on the CuPt

Flow injection analysis of phytic acid b
โœ Minori Kamaya; Tomohiro Furuki; Kunio Nagagshima ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 192 KB ๐Ÿ‘ 1 views

A simple and rapid flow-injection analysis (FIA) of phytic acid in cereal food samples is reported based on a modified molybdenum blue method. The interference from inorganic phosphate ion was eliminated by using an anion exchange resin. The samples treated with the ion exchangers were analysed usin

On-Line Analysis of Mercury by Sequentia
โœ Iva Turyan; Thomas Erichsen; Wolfgang Schuhmann; Daniel Mandler ๐Ÿ“‚ Article ๐Ÿ“… 2001 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 84 KB ๐Ÿ‘ 2 views

A highly ยฏexible, automatic sequential-injection stripping analysis (SISA) system has been developed and applied for monitoring the levels of mercury in aqueous solutions using a chemically modiยฎed electrode. The preparation of the modiยฎed electrode comprises spin coating of an ethanolic solution of