## Abstract Finite element analysis (FEA) was used to investigate the stress fields and the degrees of subsurface damage of ceramic prostheses in simulated intraoral dental resurfacing operations using clinical diamond burs. A twoโdimensional finite element model was established with the dental ope
Finite Element Analysis of the Contact Mechanics of Ceramic-on-Ceramic Hip Resurfacing Prostheses
โ Scribed by Ahmet C. Cilingir
- Publisher
- SciencePress (China)
- Year
- 2010
- Tongue
- English
- Weight
- 595 KB
- Volume
- 7
- Category
- Article
- ISSN
- 1672-6529
No coin nor oath required. For personal study only.
โฆ Synopsis
Ceramics are good alternative to metal as bearing couple materials because of their better wear resistance. A Finite Element (FE) study was performed to investigate the contact mechanics and stress distribution of Ceramic-on-Ceramic (COC) hip resurfacing prostheses. It was focused in particular on a parametric study to examine the effects of radial clearance, loading, alumina coating on the implants, bone quality, and fixation of cup-bone interface. It was found that a reduction in the radial clearance had the most significant effect on the predicted contact pressure distribution among all of the parameters considered in this study. It was determined that there was a significant influence of non-metallic materials, such as the bone underneath the bearing components, on the predicted contact mechanics. Stress shielding within the bone tissue was found to be a major concern when regarding the use of ceramic as an alternative to metallic resurfacing prostheses. Therefore, using alumina implants with a metal backing was found to be the best design for ceramic resurfacing prostheses in this study. The loading, bone quality, and acetabular cup fixation conditions were found to have only minor effects on the predicted contact pressure distribution along the bearing surfaces.
๐ SIMILAR VOLUMES
## Abstract We investigated articular bearing surfaces retrieved from three patients with ceramicโonโceramic total hip arthroplasties using highโquality alumina. The duration of implantation was 3.5, 3.0, and 2.5 years, respectively. Dislocation of the hip joint after implantation did not occur in
We present a ยฎnite element procedure for the analysis of fully coupled thermo-elasto-plastic response of solids including contact conditions. The continuum mechanics formulation for the solid and contact conditions is summarized and eective ยฎnite element techniques for solution are given. The constr