## Abstract ## Purpose: To evaluate the feasibility of the dark blood fast spin echo (FSE) T1‐weighted–Sampling Perfection with Application of optimized Contrasts using different flip angle Evolution (T1w‐SPACE) sequence in assessing whole body arterial wall information from the extracranial carot
Fast whole-body magnetic resonance angiography in mice
✍ Scribed by William Lefrançois; Eric Thiaudière; Wadie Ben Hassen; Stéphane Sanchez; Jean-Michel Franconi; Sylvain Miraux
- Publisher
- John Wiley and Sons
- Year
- 2011
- Tongue
- English
- Weight
- 380 KB
- Volume
- 66
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
High‐throughput magnetic resonance imaging (MRI) tools are required for the longitudinal investigation of vascular diseases in mouse models. Angiographic data from various anatomic regions may be needed in a single experiment. This study involves a three‐dimensional (3D) time‐of‐flight (TOF) magnetic resonance angiography (MRA) method using sequential acquisitions of four data sets corresponding to the head, the thorax, the abdomen, and the hind limbs of a mouse. After repositioning the animal, each anatomic region was acquired in 2 min, and the TOF effect was provided by the spatial selectivity of the radio frequency (RF) resonator. No slab selection was needed and whole‐body MRA was performed in a total experiment time of 10 min. The voxel size was equal to or greater than 131 × 195 × 188 μm^3^. To suppress the signal arising from stationary tissues, both inversion recovery and interspersed saturation, used as magnetization preparations, were compared from a theoretical and an experimental perspective. The arterial tree (carotid, aortic, iliac, renal, and smaller arteries) was well visualized by this method, both in control healthy mice and in mice with common carotid artery ligation. The potential interest of this method for evaluating arterial diseases is discussed. Magn Reson Med, 2011. © 2011 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract In order to enhance 3D image data from magnetic resonance angiography (MRA), a novel method based on the theory of multidimensional adaptive filtering has been developed. The purpose of the technique is to suppress image noise while enhancing important structures. The method is based on
## Abstract ## Purpose To compare volume‐targeted and whole‐heart coronary magnetic resonance angiography (MRA) after the administration of an intravascular contrast agent. ## Materials and Methods Six healthy adult subjects underwent a navigator‐gated and ‐corrected (NAV) free breathing volume‐