Multi-shot echo-planar ¯uid-attenuated inversion-recovery (EPI-Flair) was compared with spin-echo T1-weighted (SE-T1W), fast SE T2weighted (FSE-T2W), and fast Flair (F-Flair) in imaging brain tumors. In 32 patients with various different brain tumors, three reviewers independently evaluated image qu
Fast T2 relaxometry with an accelerated multi-echo spin-echo sequence
✍ Scribed by Julien Sénégas; Wei Liu; Hannes Dahnke; Hotaek Song; E. Kay Jordan; Joseph A. Frank
- Book ID
- 102957710
- Publisher
- John Wiley and Sons
- Year
- 2010
- Tongue
- English
- Weight
- 907 KB
- Volume
- 23
- Category
- Article
- ISSN
- 0952-3480
- DOI
- 10.1002/nbm.1521
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
A new method has been developed to reduce the number of phase‐encoding steps in a multi‐echo spin‐echo imaging sequence allowing fast T~2~ mapping without loss of spatial resolution. In the proposed approach, the k‐space data at each echo time were undersampled and a reconstruction algorithm that exploited the temporal correlation of the MR signal in k‐space was used to reconstruct alias‐free images. A specific application of this algorithm with multiple‐receiver acquisition, offering an alternative to existing parallel imaging methods, has also been introduced. The fast T~2~ mapping method has been validated in human brain T~2~ measurements in a group of nine volunteers with acceleration factors up to 3.4. The results demonstrated that the proposed method exhibited excellent linear correlation with the regular T~2~ mapping with full sampling and achieved better image reconstruction and T~2~ mapping with respect to SNR and reconstruction artifacts than the selected reference acceleration techniques. The new method has also been applied for quantitative tracking of injected magnetically labeled breast cancer cells in the rat brain with acceleration factors of 1.8 and 3.0. The proposed technique can provide an effective approach for accelerated T~2~ quantification, especially for experiments with single‐channel coil when parallel imaging is not applicable. Copyright © 2010 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
## Abstract The accuracy of water T2 maps generated from a fast spin‐echo (FSE) sequence was compared with data obtained by conventional single and multi‐echo spin‐echo pulse sequences using a commercial gel phantom. Spatially localized stimulated echo acquisition mode (STEAM) proton spectroscopy w
## Abstract ## Purpose To compare the abilities of T2‐weighted (T2W) imaging using respiratory‐triggered fast spin‐echo (RT‐FSE), breathhold fast‐recovery FSE (BH‐FRFSE), and BH single‐shot FSE (BH‐SSFSE) sequences without an endorectal coil to detect rectosigmoid carcinomas. ## Materials and Met
## Abstract The purpose of our study was to compare the value of respiratory‐triggered fast spin‐echo, breath‐hold single‐shot fast spin‐echo, and breath‐hold fast‐recovery fast spin‐echo sequences in detecting hepatic lesions. Fat‐suppressed T2‐weighted magnetic resonance (MR) images obtained with
## Abstract In 49 patients who had pelvic abnormalities, breath‐hold T2‐weighted fast‐recovery (FR)‐fast spin‐echo (FSE) (imaging time = 24 sec) and nonbreath‐hold FSE MR images (2 min 8 sec) were compared qualitatively (on a four‐point scale) and quantitatively (using signal‐to‐noise ratios (SNRs)
Three-dimensional (3Dl fast spin-echo (FSE) imaging can produce contiguous thin sections for high-quality multiplanar reconstructions. Such reformatted images may be useful in the evaluation of three-dimensionally complex. curvilinear anatomic structures such as the hippocampus. The authors describe