𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Fast SSFP gradient echo sequence for simultaneous acquisitions of FID and echo signals

✍ Scribed by S. Y. Lee; Z. H. Cho


Publisher
John Wiley and Sons
Year
1988
Tongue
English
Weight
508 KB
Volume
8
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Recently, the gradient echo imaging sequence in conjunction with small flip angle excitations and short repetition times has been widely used for fast NMR imaging. As the repetition time decreases to an extent comparable to the spin-spin relaxation time T2, the residual phase coherency of the transverse spin magnetization tends to form another nuclear signal which is heavily weighted by T2 and similar to a long TR/long TE spin-echo signal. This effect, although expected, has not been utilized in the conventional fast gradient echo imaging. When this residual phase coherency is utilized in conjunction with the fast SSFP (steady-state free precession) technique, both the FID and the echo signals can be obtained. In this paper, we have proposed a new technique by which simultaneous acquisitions of both the FID and the echo signals are possible. Experiments on this fast SSFP mode imaging have shown that the FID signal is T1-weighted while the echo signal is strongly T2-weighted. The flip angle optimal for maximizing signal and related contrast are also studied in conjunction with the proposed sequence and the experimental results are presented.


πŸ“œ SIMILAR VOLUMES


Simultaneous acquisition of gradient-ech
✍ Keith Arron Heberlein; Xiaoping Hu πŸ“‚ Article πŸ“… 2003 πŸ› John Wiley and Sons 🌐 English βš– 148 KB

## Abstract This article describes the Z‐SAGA pulse sequence, a technique for recovering susceptibility losses in EPI images for neuroimaging applications. The pulse sequence is based on an asymmetric spin echo EPI sequence and acquires a gradient echo image and an asymmetric spin echo image in a s

Simultaneous acquisition of gradient ech
✍ C. B. Glielmi; Q. Xu; R. C. Craddock; X. Hu πŸ“‚ Article πŸ“… 2010 πŸ› John Wiley and Sons 🌐 English βš– 445 KB

## Abstract Arterial spin labeling‐based cerebral blood flow imaging complements blood oxygenation level dependent (BOLD) imaging with a measure that is more quantitative and has better specificity to neuronal activation. Relative to gradient echo BOLD, spin echo BOLD has better spatial specificity

Comparison of three-dimensional fast spi
✍ Petra Schmalbrock πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 669 KB

T2-weighted high-resolution gradient and fast spin echo sequences are widely used as an alternative or adjunct to contrast-enhanced T1-weighted temporal bone imaging. However, to date no systematic comparison has been presented. The purpose of this work is to identify optimal acquisition parameters

Cardiac imaging: Comparison of two-shot
✍ Daniel A. Leung; JΓΆrg F. Debatin; Simon Wildermuth; Graeme C. McKinnon; Gustav K πŸ“‚ Article πŸ“… 1995 πŸ› John Wiley and Sons 🌐 English βš– 665 KB

## Abstract We compared the cardiac image quality of multishot echo‐planar imaging (EPI), segmented K‐space, and conventional cine acquisitions. Three techniques were used to obtain gated multiphase acquisitions of an axial section traversing both ventricles in 10 volunteers: two‐shot EPI acquired

Simultaneous quantification of T2 and Tβ€²
✍ Eleanor F. Cox; Penny A. Gowland πŸ“‚ Article πŸ“… 2010 πŸ› John Wiley and Sons 🌐 English βš– 322 KB

## Abstract Measuring __T__~2~ at 7.0 T is not trivial due to RF inhomogeneity effects, however, gradient echo sampling of a spin echo is insensitive to RF pulse errors, does not suffer from significant distortions, and allows __T__β€²~2~ and __T__~2~ to be estimated simultaneously. Gradient echo sam

Myocardial signal response to dipyridamo
✍ Debiao Li; Paritosh Dhawale; Patricia J. Rubin; E. Mark Haacke; Robert J. Grople πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 619 KB

## Abstract The purpose of this study was to examine the differential myocardial signal responses due to the blood oxygen level dependent (BOLD) effect in magnetic resonance imaging (MRI) under differing conditions of myocardial oxygen supply and demand. The signal response was measured when myocar