## Abstract This article describes the ZβSAGA pulse sequence, a technique for recovering susceptibility losses in EPI images for neuroimaging applications. The pulse sequence is based on an asymmetric spin echo EPI sequence and acquires a gradient echo image and an asymmetric spin echo image in a s
Fast SSFP gradient echo sequence for simultaneous acquisitions of FID and echo signals
β Scribed by S. Y. Lee; Z. H. Cho
- Publisher
- John Wiley and Sons
- Year
- 1988
- Tongue
- English
- Weight
- 508 KB
- Volume
- 8
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
β¦ Synopsis
Recently, the gradient echo imaging sequence in conjunction with small flip angle excitations and short repetition times has been widely used for fast NMR imaging. As the repetition time decreases to an extent comparable to the spin-spin relaxation time T2, the residual phase coherency of the transverse spin magnetization tends to form another nuclear signal which is heavily weighted by T2 and similar to a long TR/long TE spin-echo signal. This effect, although expected, has not been utilized in the conventional fast gradient echo imaging. When this residual phase coherency is utilized in conjunction with the fast SSFP (steady-state free precession) technique, both the FID and the echo signals can be obtained. In this paper, we have proposed a new technique by which simultaneous acquisitions of both the FID and the echo signals are possible. Experiments on this fast SSFP mode imaging have shown that the FID signal is T1-weighted while the echo signal is strongly T2-weighted. The flip angle optimal for maximizing signal and related contrast are also studied in conjunction with the proposed sequence and the experimental results are presented.
π SIMILAR VOLUMES
## Abstract Arterial spin labelingβbased cerebral blood flow imaging complements blood oxygenation level dependent (BOLD) imaging with a measure that is more quantitative and has better specificity to neuronal activation. Relative to gradient echo BOLD, spin echo BOLD has better spatial specificity
T2-weighted high-resolution gradient and fast spin echo sequences are widely used as an alternative or adjunct to contrast-enhanced T1-weighted temporal bone imaging. However, to date no systematic comparison has been presented. The purpose of this work is to identify optimal acquisition parameters
## Abstract We compared the cardiac image quality of multishot echoβplanar imaging (EPI), segmented Kβspace, and conventional cine acquisitions. Three techniques were used to obtain gated multiphase acquisitions of an axial section traversing both ventricles in 10 volunteers: twoβshot EPI acquired
## Abstract Measuring __T__~2~ at 7.0 T is not trivial due to RF inhomogeneity effects, however, gradient echo sampling of a spin echo is insensitive to RF pulse errors, does not suffer from significant distortions, and allows __T__β²~2~ and __T__~2~ to be estimated simultaneously. Gradient echo sam
## Abstract The purpose of this study was to examine the differential myocardial signal responses due to the blood oxygen level dependent (BOLD) effect in magnetic resonance imaging (MRI) under differing conditions of myocardial oxygen supply and demand. The signal response was measured when myocar