𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Fast simultaneous quantitative analysis of FTY720 and its metabolite FTY720-P in human blood by on-line solid phase extraction coupled with liquid chromatography–tandem mass spectrometry

✍ Scribed by Corinne Emotte; Fany Deglave; Olivier Heudi; Franck Picard; Olivier Kretz


Book ID
113743205
Publisher
Elsevier Science
Year
2012
Tongue
English
Weight
576 KB
Volume
58
Category
Article
ISSN
0731-7085

No coin nor oath required. For personal study only.

✦ Synopsis


Fingolimod (Gilenya ® ; FTY720), has been recently approved for the treatment of multiple sclerosis in Europe and in the USA. In the present study, we have developed and validated a rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to simultaneously quantify FTY720 and FTY720-P in human blood. The sample preparation involves the sample dilution with a solution made of dimethylhexylamine (DMHA), ortho-phosphoric acid and methanol prior to the on-line solid phase extraction (SPE) on a C 18 cartridge. The samples were then eluted on a C 18 column with a gradient elution of DMHA solution and acetonitrile and analyzed by LC-MS/MS using electrospay ionization in positive mode. The analysis time between 2 samples was 7.5 min. Standard curves were linear over the ranges of 0.0800 ng/mL (LLOQ) to 16.0 ng/mL for FTY720 and 0.100 ng/mL (LLOQ) to 20.0 ng/mL for FTY720-P with correlation coefficient (r 2 ) greater than 0.997. The method selectivities for FTY720 and FTY720-P were demonstrated in six different batches of human blood. Intra-run and inter-run precision and accuracy within ±20% (at the LLOQ) and ±15% (other levels) were achieved during a 3-run validation for quality control samples (QCs). In addition, stability data obtained during freeze-thaw (3 cycles), at room temperature (24 h), and in an auto-sampler were determined and reported. The method robustness was demonstrated by the consistent data obtained by reanalyzing human blood samples for several clinical studies. In addition comparative data for FTY720 and FTY720-P were obtained between our current method and those of two available separate LC-MS/MS assays. The results of the present work demonstrated that our bioanalytical LC-MS/MS method is rapid, sensitive, specific and reliable for the simultaneous quantitative analysis of FTY720 and FTY720-P in human blood.


📜 SIMILAR VOLUMES


Fully automated determination of eserine
✍ Pruvost, A.; Ragueneau, I.; Ferry, A.; Jaillon, P.; Grognet, J.-M.; Benech, H. 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 109 KB 👁 3 views

A sensitive and entirely automated solid-phase extraction/liquid chromatography/electrospray ionization tandem mass spectrometric (SPE/LC/ESI-MS/MS) method was developed and validated for the determination of eserine N -oxide (ENO), a cholinesterase inhibitor-like physostigmine in human plasma, for

Determination of didanosine in human ser
✍ Rita de Cassia E. Estrela; Myriam C. Salvadori; Renata S. L. Raices; Guilherme S 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 164 KB 👁 2 views

## Abstract A method based on solid‐phase extraction coupled to liquid chromatography with positive ion electrospray ionization and tandem mass spectrometric detection was developed for the determination of didanosine in human serum, using lamivudine as internal standard. The acquisition was perfor