𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Fast perfluorocarbon imaging using 19F U-FLARE

✍ Scribed by P. Börnert; D. G. Norris; H. Koch; W. Dreher; H. Reichelt; D. Leibfritz


Publisher
John Wiley and Sons
Year
1993
Tongue
English
Weight
996 KB
Volume
29
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The application of an ultra‐fast low angle RARE technique for the ^19^F imaging of perfluorocarbons (PFCs) used as temporary blood substitutes is described. This sequence is attractive for fast ^19^F imaging studies that measure the biodistribution of PFCs in vivo, due to its high signal‐to‐noise ratio. Extensions of this technique for the chemical shift selective measurement of fluorine T~1~ values are presented. Using the linear dependence between the oxygen partial pressure (pO~2~) and the T~1~ relaxation rate of PFC resonances this technique makes possible the fast in vivo measurement of oxygen tension. Using the sequence in a diffusion sensitized form ^19^F measurements of the diffusion constants of PFCs are also presented. Phantom experiments to test the methods, and in vivo images obtained in rat studies are given and discussed.


📜 SIMILAR VOLUMES


Improvements in 19F NMR imaging in perfl
✍ Peter Börnert; Wolfgang Dreher; Achim Gössler; Günter Klee; Rolf Peter; Wilfried 📂 Article 📅 1987 🏛 Elsevier Science 🌐 English ⚖ 821 KB

The application of an improved imaging sequence for i9F NMR imaging in perlhtorotributylamine is discussed and the results of phantom studies are reported. Frequency-selective excitation by a l-3-3-1 hard pulse sequence and a short echo time are used to increase the signal-to-noise ratio. In this wa

Fast U-FLARE-based correlation-peak imag
✍ Dirk Mayer; Wolfgang Dreher; Dieter Leibfritz 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 333 KB

## Abstract A new fast correlation‐peak imaging technique is presented that combines 2D correlation spectroscopy with an ultrafast low‐angle rapid acquisition with relaxation enhancement (U‐FLARE) imaging module. Constant time chemical shift (CS) encoding is used in both time dimensions to achieve

A Fast Variant of 1H Spectroscopic U-FLA
✍ Andreas Ebel; Wolfgang Dreher; Dieter Leibfritz 📂 Article 📅 2000 🏛 Elsevier Science 🌐 English ⚖ 315 KB

So far, fast spectroscopic imaging (SI) using the U-FLARE sequence has provided metabolic maps indirectly via Fourier transformation (FT) along the chemical shift (CS) dimension and subsequent peak integration. However, a large number of CS encoding steps N is needed to cover the spectral bandwidth

Oxygen tension mapping with F-19 echo-pl
✍ Bruce R. Barker; Ralph P. Mason; Navin Bansal; Ronald M. Peshock 📂 Article 📅 1994 🏛 John Wiley and Sons 🌐 English ⚖ 913 KB

## Abstract The authors used fluorine‐19 inversion‐recovery (IR) echo‐planar imaging (EPI) to map oxygen tension on the basis of the spin‐lattice relaxation rate (R1) of sequestered perfluorocarbon. R1 measured with IR‐EPI varied as a linear function of oxygen tension and temperature, and the relat

Quantitative molecular imaging of athero
✍ Lei Zhang; Huiying Zhang; Kristin Bibee; John Allen; Junjie Chen; Gregory M Lanz 📂 Article 📅 2010 🏛 BioMed Central 🌐 English ⚖ 653 KB