Fast perfluorocarbon imaging using 19F U-FLARE
✍ Scribed by P. Börnert; D. G. Norris; H. Koch; W. Dreher; H. Reichelt; D. Leibfritz
- Publisher
- John Wiley and Sons
- Year
- 1993
- Tongue
- English
- Weight
- 996 KB
- Volume
- 29
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The application of an ultra‐fast low angle RARE technique for the ^19^F imaging of perfluorocarbons (PFCs) used as temporary blood substitutes is described. This sequence is attractive for fast ^19^F imaging studies that measure the biodistribution of PFCs in vivo, due to its high signal‐to‐noise ratio. Extensions of this technique for the chemical shift selective measurement of fluorine T~1~ values are presented. Using the linear dependence between the oxygen partial pressure (pO~2~) and the T~1~ relaxation rate of PFC resonances this technique makes possible the fast in vivo measurement of oxygen tension. Using the sequence in a diffusion sensitized form ^19^F measurements of the diffusion constants of PFCs are also presented. Phantom experiments to test the methods, and in vivo images obtained in rat studies are given and discussed.
📜 SIMILAR VOLUMES
The application of an improved imaging sequence for i9F NMR imaging in perlhtorotributylamine is discussed and the results of phantom studies are reported. Frequency-selective excitation by a l-3-3-1 hard pulse sequence and a short echo time are used to increase the signal-to-noise ratio. In this wa
## Abstract A new fast correlation‐peak imaging technique is presented that combines 2D correlation spectroscopy with an ultrafast low‐angle rapid acquisition with relaxation enhancement (U‐FLARE) imaging module. Constant time chemical shift (CS) encoding is used in both time dimensions to achieve
So far, fast spectroscopic imaging (SI) using the U-FLARE sequence has provided metabolic maps indirectly via Fourier transformation (FT) along the chemical shift (CS) dimension and subsequent peak integration. However, a large number of CS encoding steps N is needed to cover the spectral bandwidth
## Abstract The authors used fluorine‐19 inversion‐recovery (IR) echo‐planar imaging (EPI) to map oxygen tension on the basis of the spin‐lattice relaxation rate (R1) of sequestered perfluorocarbon. R1 measured with IR‐EPI varied as a linear function of oxygen tension and temperature, and the relat
Publish with Bio Med Central and every scientist can read your work free of charge "BioMed Central will be the most significant development for disseminating the results of biomedical researc h in our lifetime.