## Abstract In this paper, we employ the hybrid finite difference–moment method to predict the shielding effectiveness (SE) of a metallic enclosure with multiple apertures. The numerical results for various aperture configurations using the hybrid technique are presented and validated. It is found
Fast computation of shielding effectiveness of metallic enclosures with apertures and inner elements
✍ Scribed by Antonio J. Lozano-Guerrero; Alejandro Díaz-Morcillo; Miguel Á. García-Fernández; Juan V. Balbastre-Tejedor
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 260 KB
- Volume
- 51
- Category
- Article
- ISSN
- 0895-2477
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
In this study, radiated immunity and emission of a metallic box with apertures have been evaluated through a fast approach. The influence of printed circuit boards inside the enclosure has been studied and also the effect of placing conductive polymer sheets in the housing to characterize the behavior of these materials used nowadays for shielding cabinets. Measurements have been carried out in anechoic chamber to evaluate the approximated technique showing its limitations and advantages. As good agreement has been found between simulations and measurements, this approach can be used for design or optimization purposes with the main advantage of reduced time calculations. © 2009 Wiley Periodicals, Inc. Microwave Opt Technol Lett 51: 2832–2836, 2009; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.24745
📜 SIMILAR VOLUMES
## Abstract This letter shows a method for approximately calculating the shielding effectiveness of a rectangular enclosure with thick multiple apertures. Numerical results illustrate the shielding effectiveness of the enclosure with various thicknesses and aperture spacings. This method is reasona