## Abstract Chemical exchange saturation transfer (CEST) MRI has been shown capable of detecting dilute labile protons and abnormal tissue glucose/oxygen metabolism, and thus, may serve as a complementary imaging technique to the conventional MRI methods. CEST imaging, however, is also dependent on
Fast 3D chemical exchange saturation transfer (CEST) imaging of the human brain
✍ Scribed by He Zhu; Craig K. Jones; Peter C. M. van Zijl; Peter B. Barker; Jinyuan Zhou
- Publisher
- John Wiley and Sons
- Year
- 2010
- Tongue
- English
- Weight
- 553 KB
- Volume
- 64
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Chemical exchange saturation transfer magnetic resonance imaging can detect low‐concentration compounds with exchangeable protons through saturation transfer to water. This technique is generally slow, as it requires acquisition of saturation images at multiple frequencies. In addition, multislice imaging is complicated by saturation effects differing from slice to slice because of relaxation losses. In this study, a fast three‐dimensional chemical exchange saturation transfer imaging sequence is presented that allows whole‐brain coverage for a frequency‐dependent saturation spectrum (z‐spectrum, 26 frequencies) in less than 10 min. The approach employs a three‐dimensional gradient‐ and spin‐echo readout using a prototype 32‐channel phased‐array coil, combined with two‐dimensional sensitivity encoding accelerations. Results from a homogenous protein‐containing phantom at 3T show that the sequence produced a uniform contrast across all slices. To show translational feasibility, scans were also performed on five healthy human subjects. Results for chemical exchange saturation transfer images at 3.5 ppm downfield of the water resonance, so‐called amide proton transfer images, show that lipid signals are sufficiently suppressed and artifacts caused by B~0~ inhomogeneity can be removed in postprocessing. The scan time and image quality of these in vivo results show that three‐dimensional chemical exchange saturation trasfer MRI using gradient‐ and spin‐echo acquisition is feasible for whole‐brain chemical exchange saturation transfer studies at 3T in a clinical time frame. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract Chemical exchange saturation transfer (CEST) MRI provides a sensitive detection mechanism that allows characterization of dilute labile protons usually undetectable by conventional MRI. Particularly, amide proton transfer (APT) imaging, a variant of CEST MRI, has been shown capable of d
## Abstract The ability to measure proton exchange rates in tissue using MRI would be very useful for quantitative assessment of magnetization transfer properties, both in conventional MT imaging and in the more recent chemical exchange saturation transfer (CEST) approach. CEST is a new MR contrast
Multivoxel 3D localized proton spectroscopy using a hybrid of 1D 8th-order transverse Hadamard spectroscopic imaging (HSI) with 2D chemical shift imaging (CSI) is demonstrated in human brain. The spatially selective HSI pulse incorporates naturally into the PRESS sequence (TE = 135 ms), which then b
## Abstract We report acquisition of 3D image‐guided localized proton spectroscopy (^1^H‐MRS) in the human brain on a standard clinical imager. 3D coverage is achieved with a hybrid of chemical shift imaging (CSI) and transverse Hadamard spectroscopic imaging (HSI). 16 × 16 × 4 arrays of 3.5 and 1