𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Factors contributing to peak broadening and mass accuracy in the characterization of intact spores using matrix-assisted laser desorption/ionization coupled with time-of-flight mass spectrometry

✍ Scribed by Javier Ramirez; Catherine Fenselau


Publisher
John Wiley and Sons
Year
2001
Tongue
English
Weight
163 KB
Volume
36
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Factors contributing to peak broadening, accuracy and precision in mass assignment in the matrix‐assisted laser desorption/ionization characterization of a lipopeptide desorbed from intact Bacillus spores were investigated. These spores were studied as an example of a thick, topologically irregular sample, which present a more difficult target than a pure peptide or protein. The type of matrix, matrix:sample ratio, laser fluence, and localized repetitive laser irradiation were all found to affect the full‐width at half maximum of the biomarker. Both in‐source and post‐source phenomena were shown to contribute. Sample thickness had less effect. Precision and accuracy of mass assignment were also affected by matrix:sample ratio and laser fluence. In general, this sample was responsive to the same experimental variables as pure peptides, and the use of an internal standard produced significant improvements in precision and accuracy. Copyright © 2001 John Wiley & Sons, Ltd.


📜 SIMILAR VOLUMES


Peptide mapping using capillary electrop
✍ Stefan Bachmann; Rania Bakry; Christian W. Huck; Fabio Polato; Danilo Corradini; 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 309 KB 👁 2 views

## Abstract This article reports the results of a study carried out to evaluate the offline hyphenation of capillary zone electrophoresis with matrix‐assisted lased desorption ionization time of flight mass spectrometry (MALDI‐TOF‐MS) for the analysis of low‐abundant complex samples, represented by

High-resolution Mass Spectrometry and Ac
✍ Russell, David H.; Edmondson, Ricky D. 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 434 KB 👁 2 views

Fundamental concepts of high-resolution mass spectrometry as it relates to the issue of accurate mass measurements are presented. Important issues speciÐc to magnetic sector instruments, Fourier transform ion cyclotron resonance and time-of-Ñight (TOF) methods are discussed. Recent high-resolution T

Rapid Identification of Intact Whole Bac
✍ R. D. Holland; J. G. Wilkes; F. Rafii; J. B. Sutherland; C. C. Persons; K. J. Vo 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 476 KB 👁 2 views

Matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) was investigated as a method for the rapid identification of whole bacteria, either by comparison with archived reference spectra or by co-analysis with cultures of known bacteria. Bacteria were sampled from c

Metallocenes as cationizing agents in th
✍ Sara K. Poehlein; Shelly J. Dormady; David R. McMillin; Fred E. Regnier 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 176 KB 👁 2 views

## Very little work has been done on exploring the transition metals as suitable cationizing agents for the analysis of polymers by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF ). This paper reports on the characterization of polystyrenes and polyethylene glycols with sele

Capillary liquid chromatography interfac
✍ Miliotis, Tasso; Kjellstr�m, Sven; Nilsson, Johan; Laurell, Thomas; Edholm, Lars 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 460 KB 👁 2 views

A piezoelectric flow-through microdispenser interfacing capillary liquid chromatography (LC) with matrixassisted laser desorption/ionization time-of-fight mass spectrometry (MALDI-TOF MS) was developed for the identification of biomolecules. The MALDI target plate was placed on a computer controlled