๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Extending the detection limit of solid-phase electrochemical enzyme immunoassay to the attomole level

โœ Scribed by Sarah H. Jenkins; William R. Heineman; H.Brian Halsall


Publisher
Elsevier Science
Year
1988
Tongue
English
Weight
606 KB
Volume
168
Category
Article
ISSN
0003-2697

No coin nor oath required. For personal study only.

โœฆ Synopsis


Electrochemical enzyme immunoassay methodology has been developed to take advantage of the selectivity of antibody reactions, the amplification feature of an enzyme-based assay, and the ease with which small amounts of the enzyme-generated product can be detected electrochemically. A heterogeneous sandwich enzyme immunoassay was used in this work as the model assay. In this type of assay, the antigen is sandwiched between the enzyme conjugate and a primary antibody that is adsorbed to the solid phase. Alkaline phosphatase is a suitable enzyme for electrochemical assays since it catalyzes the conversion of electroinactive phenyl phosphate to electroactive phenol. The product, phenol, is then quantitated by liquid chromatography with electrochemical detection in a thin-layer flow cell with a carbon paste electrode at 0.895 V vs Ag/AgCl. The current produced by the oxidation of phenol is directly proportional to the analyte (antigen) concentration. The problem associated with these types of solid-phase immunoassays is that the adsorption of the primary antibody is desired while the adsorption of other assay proteins is not. The detection limits are generally defined by the ability to control this nonspecific adsorption. The detection limit of a previous electrochemical assay for rabbit IgG was 100 pg/ml and was limited by a large background current observed in the absence of antigen. In the present study, each step of the assay was examined in order to determine the sources of this background current, and it was found that the major contribution was from the nonspecific adsorption of the enzyme conjugate. Using combinations of Tween 20 and bovine serum albumin as blocking agents, the level of nonspecific adsorption was reduced by 96%.(ABSTRACT TRUNCATED AT 250 WORDS)


๐Ÿ“œ SIMILAR VOLUMES


Solid-phase electrochemical enzyme immun
โœ Yan Xu; H.Brian Halsall; William R. Heineman ๐Ÿ“‚ Article ๐Ÿ“… 1989 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 716 KB

A sandwich electrochemical enzyme immunoassay with flow injection analysis for the model antigen mouse IgG has been developed with alkaline phosphatase as the enzyme label. The enzyme substrate, 4-aminophenyl phosphate and its enzymatic reaction product, 4-aminophenol have been studied by cyclic and

Automatic apparatus for heterogeneous en
โœ Denis Huet; Christian Bourdillon ๐Ÿ“‚ Article ๐Ÿ“… 1993 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 794 KB

A glassy carbon electrode, anodized for a short tune at about 2 2 V vs SCE, IS a very convenient regenerable solid phase for the suCCesswe stages of an automated enzyme-linked immunosorbent assay The anodized surface adsorbs the pnmary antibody and the blockmg protems m a snmlar manner to class& pol