Experimental and computational models to investigate the effect of adhesion on the mechanical properties of bone-cement composites
✍ Scribed by B. Helgason; P. Stirnimann; R. Widmer; S. J. Ferguson
- Publisher
- John Wiley and Sons
- Year
- 2011
- Tongue
- English
- Weight
- 820 KB
- Volume
- 99B
- Category
- Article
- ISSN
- 1552-4973
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
A generic finite element approach was developed to study the effect of adhesion on the mechanical response of bone cement composites and validated against literature data. The results showed that a zero friction bone‐cement (PMMA) interface conditions captured the results of the experimental testing better than assuming a fully bonded interface. An experimental model for studying the effect of interface adhesion in a bone‐cement like composite was also developed in the present study. The results using this model indicate that the difference in Young's modulus and ultimate strength between a fully bonded interface and unbonded interface is approximately 30% for bone volume fraction similar to what can be found in osteoporotic vertebrae. Apart from concluding that bone to cement adhesion is a major contributor to the mechanical response of bone‐cement composites, our studies based on the generic FE approach also indicate that the mechanical properties of the cement is the most important contributor to the resulting mechanical properties of the composite at bone volume fraction relevant in terms of vertebroplasty treatment. © 2011 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2011.
📜 SIMILAR VOLUMES
## Abstract **Summary:** The effect of silica and its surface treatment on the mechanical properties of composites was studied as part of the evaluation of cyanate ester matrices as potential electronic encapsulants. Three filler surface treatments were used, as a qualitative interfacial adhesion s
## Abstract Polymethylmethacrylate bone cement, containing either no added antibiotic, 0.5 g of Vancomycin, 1.0 g of Vancomycin, or 1.0 g of Tobramycin, was mixed either in air or a vacuum chamber. Following storage in a water bath at 37°C for 48 h, the specimens were tested in four‐point bending.
## Abstract Early work on hip prosthesis showed that the metal component would loosen in bone even when screws were used. This practice resulted in the death and resorption of the bone; thus cement was used in orthopedic surgery for firm implantation of prostheses. In recent years antibiotics have
## Abstract The procedure percutaneous vertebroplasty consists of injecting polymethylmethacrylate cement into vertebral bodies for the treatment of osteoporotic compression fractures and tumors of the spine. Clinicians practicing vertebroplasty commonly alter the mixture of monomer‐to‐powder recom
## Abstract **Summary:** New injectable, in situ curable liquid formulations consisting of biodegradable aliphatic polyester, i.e., poly(3‐allyloxy‐1,2‐propylene)succinate (PSAGE), methyl methacrylate (MMA), and hydrophilic oligo(ethylene glycol) dimethacrylates (OEGDMA) were investigated. The effe