✦ Synopsis


Abstract

Relative to common clinical magnetic field strengths, higher fields benefit functional brain imaging both by providing additional signal for high‐resolution applications and by improving the sensitivity of endogenous contrast due to the blood oxygen level dependent (BOLD) mechanism, which has limited detection power at low magnetic fields relative to the use of exogenous contrast agent. This study evaluates the utility of iron oxide contrast agent for gradient echo functional MRI at 9.4 T in rodents using cocaine and methylphenidate as stimuli. Relative to the BOLD method, the use of high iron doses and short echo times provided a roughly twofold global increase in functional sensitivity, while also suppressing large vessel signal and reducing susceptibility artifacts. Furthermore, MRI measurements of the functional percentage change in cerebral blood volume (CBV) showed excellent agreement with results obtained at much lower magnetic field strengths, demonstrating that MRI estimates of this quantity are roughly independent of magnetic field when appropriate techniques are employed. The derived field dependencies for relative sensitivity and MRI estimates of the percentage change in CBV suggest that the benefits provided by exogenous agents will persist even at much higher magnetic fields than 9.4 T. Magn Reson Med 52:1272–1281, 2004. © 2004 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Fat suppression gradient-echo magnetic r
✍ Kari Palosaari; Risto Ojala; Roberto Blanco-Sequeiros; Osmo Tervonen 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 716 KB

## Purpose: To evaluate the diagnostic performance of a newly developed single-scan phase-contrast water-fat imaging technique for fat suppression at 0.23t open magnet, compared to the conventional chemical shift selective fat suppression method at 1.5t, in the detection of experimental articular c

Vital signs and cognitive function are n
✍ Ian C. Atkinson; Rachel Sonstegaard; Neil H. Pliskin; Keith R. Thulborn 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 193 KB 👁 1 views

## Abstract ## Purpose: To evaluate the effect of 23‐sodium (^23^Na) and 17‐oxygen (^17^O) magnetic resonance imaging (MRI) at 9.4 (T) on vital signs and cognitive function of the human brain. ## Materials and Methods: Vital sign and cognitive function measurements from healthy volunteers (__N__