## Abstract In this study we investigated the feasibility of performing 3D timeβofβflight magnetic resonance angiography to remotely image the arteries of rat spinal cord. Using a customβdesigned implantable radiofrequency coil, we acquired angiograms from normal and injured cords. The potential of
Ex vivo magnetic resonance imaging of rat spinal cord at 9.4 T
β Scribed by Mehmet Bilgen; Baraa Al-Hafez; Thomas M. Malone; Irina V. Smirnova
- Book ID
- 104060218
- Publisher
- Elsevier Science
- Year
- 2005
- Tongue
- English
- Weight
- 184 KB
- Volume
- 23
- Category
- Article
- ISSN
- 0730-725X
No coin nor oath required. For personal study only.
β¦ Synopsis
The magnetic resonance (MR) properties of the rat spinal cord were characterized at the T9 level with ex vivo experiments performed at 9.4 T. The inherent endogenous contrast parameters, proton density (PD), longitudinal and transverse relaxation times T1 and T2, and magnetization transfer ratio (MTR) were measured separately for the grey matter (GM) and white matter (WM). Analysis of the measurements indicated that these tissues have statistically different proton densities with means PD(GM)=54.8+/-2.5% versus PD(WM)=45.2+/-2.4%, and different T1 values with means T1GM=2.28+/-0.23 s versus T1WM=1.97+/-0.21 s. The corresponding values for T2 were T2GM=31.8+/-4.9 ms versus T2WM=29.5+/-4.9 ms, and the difference was insignificant. The difference between MTR(GM)=31.2+/-6.1% and MTR(WM)=33.1+/-5.9% was also insignificant. These results collectively suggest that PD and T1 are the two most important parameters that determine the observed contrast on spinal cord images acquired at 9.4 T. Therefore, in MR imaging studies of spinal cord at this field strength, these parameters need to be considered not only in optimizing the protocols but also in signal enhancement strategies involving exogenous contrast agents.
π SIMILAR VOLUMES
## Abstract ## Purpose To determine differences in diffusion measurements in white matter (WM) and gray matter (GM) regions of the rat cervical, thoracic, and cauda equina spinal cord using in vivo diffusion tensor imaging (DTI) with a 9.4T MR scanner. ## Materials and Methods DTI was performed
## Abstract An inductively coupled implanted coil was designed for highβresolution magnetic resonance (MR) studies of rat spinal cord (SC) in vivo at 7 T. The practical issues involved in implementation of the coil at high fields are discussed, and the adjustment of various parameters for optimizin
## Purpose: To demonstrate the feasibility of obtaining high-quality magnetic resonance (mr) images of the human cervical spinal cord in vivo at a magnetic field strength of 3 t and to optimize the signal contrast between gray matter, white matter, and cerebrospinal fluid (csf) on 2d gradient recal