๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Magnetic resonance angiography of rat spinal cord at 9.4 T: A feasibility study

โœ Scribed by Mehmet Bilgen; Baraa Al-Hafez; Yong-Yue He; William M. Brooks


Publisher
John Wiley and Sons
Year
2005
Tongue
English
Weight
247 KB
Volume
53
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

โœฆ Synopsis


Abstract

In this study we investigated the feasibility of performing 3D timeโ€ofโ€flight magnetic resonance angiography to remotely image the arteries of rat spinal cord. Using a customโ€designed implantable radiofrequency coil, we acquired angiograms from normal and injured cords. The potential of the approach was evaluated in terms of longitudinally monitoring the vascular reorganization of spinal cord following an injury. Magn Reson Med 53:1459โ€“1461, 2005. ยฉ 2005 Wileyโ€Liss, Inc.


๐Ÿ“œ SIMILAR VOLUMES


In vivo magnetic resonance microscopy of
โœ Mehmet Bilgen; Ibrahim Elshafiey; Ponnada A. Narayana ๐Ÿ“‚ Article ๐Ÿ“… 2001 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 175 KB

## Abstract An inductively coupled implanted coil was designed for highโ€resolution magnetic resonance (MR) studies of rat spinal cord (SC) in vivo at 7 T. The practical issues involved in implementation of the coil at high fields are discussed, and the adjustment of various parameters for optimizin

Level of termination of the spinal cord
โœ Andrew Macdonald; Paul Chatrath; Tim Spector; Harold Ellis ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 131 KB ๐Ÿ‘ 1 views

Previous studies concerning the level of termination of the human spinal cord have been carried out in unselected cadavers. We have used magnetic resonance imaging to determine this level of termination, and that of the dural sac, in normal living subjects. We found a wider range of the level of ter

Diffusion tensor imaging of in vivo and
โœ Saaussan Madi; Khader M. Hasan; Ponnada A. Narayana ๐Ÿ“‚ Article ๐Ÿ“… 2004 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 318 KB

## Abstract Regional values of fractional anisotropy (FA) and mean diffusivity (__D__~av~) of in vivo and excised rat spinal cords were measured using an iscosahedral encoding scheme that is based on 21 uniformly distributed and alternating gradient directions with an echo planar imaging (EPI) read

Assessment of dynamic susceptibility con
โœ Stephen E. Rose; Andrew L. Janke; Mark W. Strudwick; Katie L. McMahon; Jonathan ๐Ÿ“‚ Article ๐Ÿ“… 2005 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 393 KB

## Abstract Pharmacological MRI (phMRI) techniques can be used to monitor the neurophysiological effects of central nervous system (CNS) active drugs. In this study, we investigated whether dynamic susceptibility contrast (DSC) perfusion imaging employing the use of superparamagnetic iron oxide nan