Ex vivo evaluation of ferromagnetism and artifacts of cardiac occluders exposed to a 1.5-T MR system

✍ Scribed by Frank G. Shellock; Stacy M. Morisoli


Publisher
John Wiley and Sons
Year
1994
Tongue
English
Weight
360 KB
Volume
4
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Magnetic resonance (MR) procedures are contraindicated for patients with certain ferromagnetic biomedical implants, primarily owing to the risk of movement or dislodgment of the implants by the static magnetic field. An additional concern is the amount of artifact that the implant produces, which can affect image quality and interpretation of the examination. Therefore, an ex vivo assessment of ferromagnetism and artifact was conducted for 12 different occluders used to treat patients with patent ductus arteriosus, atrial septal defects, and ventricular septal defects, in a 1.5‐T MR system. Seven of the occluders, made of 304 stainless steel, were ferromagnetic and displayed deflection forces of 248–299 dynes. Five of the implants, made of MP35n, were nonferromagnetic. Artifacts were variable and depended primarily on the type and amount of metal used to construct the implant. The authors conclude that patients with ferromagnetic cardiac occluders may undergo MR procedures approximately 6 weeks after placement of these devices, to allow tissue growth to provide additional retentive force. After this time, it is highly unlikely that the magnetic fields associated with a 1.5‐T MR system are capable of moving or dislodging any of these cardiac occluders.


πŸ“œ SIMILAR VOLUMES


Ex Vivo Evaluation of Ferromagnetism, He
✍ Linda-Lynn Pagan; Frank G. Shellock; R. James Brenner; Barry Rothman πŸ“‚ Article πŸ“… 1995 πŸ› John Wiley and Sons 🌐 English βš– 357 KB

## Abstract Three breast tissue expanders were evaluated for compatibility with MR imaging (1.5 Tesla). The metallic components of the breast tissue expanders were shown to be nonferromagnetic, heating .2Β°C and the artifacts varied. These results indicate that MR procedures may be performed safely

Ex vivo evaluation of ferromagnetism, he
✍ Frank G. Shellock; Stacy M. Morisoli πŸ“‚ Article πŸ“… 1994 πŸ› John Wiley and Sons 🌐 English βš– 293 KB

## Abstract Ex vivo testing techniques were used to determine the ferromagnetic qualities of, presence of heating in, and artifacts produced by 13 different heart valve prostheses exposed to a 1.5‐T (64‐MHz) magnetic resonance (MR) system. None of the heart valve prostheses showed a measurable defl

Hr imaging and vascular access ports: Ex
✍ Frank G. Shellock; Marcia Nogueira; Stacy Morisoli πŸ“‚ Article πŸ“… 1995 πŸ› John Wiley and Sons 🌐 English βš– 508 KB

## Abstract The purpose of our study was to asacsa Futomagneh. hating. ad artifactr, associated with vabcular access ports exposed to a 1.5‐T MR system. Tweaty‐cight different vabcular access port. were evaluated in thb investlgation. Fmmagnetism was determined by using two previouely de techniques

Biopsy needles and devices: Assessment o
✍ Marleigh A. Moscatel; Frank G. Shellock; Stacy M. Morisoli πŸ“‚ Article πŸ“… 1995 πŸ› John Wiley and Sons 🌐 English βš– 398 KB

## Forty -eight biopsy devices (needles, stylets, guide wires. biopsy guns. etc) were evaluated for ferromagnetism (n = 48) and artifacts (n = 43) in a 1.5-T magnetic resonance (MR) system, with previously deflve of the 48 devices were found to be ferromagnetic. Artifacts varied, depending on the