𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Evaluation of atomic fluorescence spectrometry as a sensitive detection technique for arsenic speciation

✍ Scribed by J. L. Gomez-Ariza; D. Sánchez-Rodas; R. Beltran; W. Corns; P. Stockwel


Publisher
John Wiley and Sons
Year
1998
Tongue
English
Weight
149 KB
Volume
12
Category
Article
ISSN
0268-2605

No coin nor oath required. For personal study only.

✦ Synopsis


The potential of coupling anion-exchange highperformance liquid chromatography, hydride generation and atomic fluorescence spectrometry (HPLC-HG-AFS) for arsenic speciation is considered. The effects of hydrochloric acid and sodium tetrahydroborate concentrations on signal-to-background ratio, as well as argon and hydrogen flow rates, were investigated. Detection limits for arsenite, dimethylarsinic acid (DMA), monomethylarsonic acid (MMA) and arsenate were 0.17, 0.45, 0.30 and 0.38 mg l À1 , respectively, using a 20-ml loop. Linearity ranges were 0.1-500 ng for As(III) and MMA (as arsenic), and 0.1-800 ng for DMA and As(V) (as arsenic). Arsenobetaine (AsB) was also determined by introducing an on-line photooxidation step after the chromatographic separation. In this case the limits of detection and linear ranges for the different species studied were similar to the values obtained previously for As(V). The technique was tested with a human urine reference material and a volunteer's sample.


📜 SIMILAR VOLUMES


Comparison of extraction procedures for
✍ M. Montperrus; Y. Bohari; M. Bueno; A. Astruc; M. Astruc 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 134 KB 👁 2 views

## Abstract Water and ‘soft’ extractions (hydroxylammonium hydrochloride, ammonium oxalate and orthophosphoric acid) have been studied and applied to the determination of arsenic species (arsenite, arsenate, monomethylarsonic acid (MMA) and dimethylarsinic acid (DMA)) in three environmental solid r

Capillary electrophoresis with laser-ind
✍ Laura Annovazzi; Simona Viglio; Eleonora Perani; Maurizio Luisetti; James Barani 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 145 KB 👁 2 views

## Abstract Among various biomarkers believed to behave as descriptors of the disease process in chronic obstructive pulmonary disease (COPD), urinary desmosines are commonly used for monitoring elastin degradation. Given the low concentrations of urinary desmosines, their quantitative determinatio

A comparative evaluation of continuous f
✍ Silvia A. Coran; Massimo Bambagiotti-Alberti; Valerio Giannellini; Gloriano Mone 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 81 KB 👁 2 views

This study compares the performances of two mass spectrometric ionization techniques, i.e. fast atom bombardment (FAB) and ion spray ionization (ISI), in the simultaneous quantitation of dodecyl-, tetradecyl-and hexadecyltrimethylammonium halides in aqueous media. Continuous flow FAB and flow inject