## Abstract HIV diagnosis at the point‐of‐care or in resource‐limited settings poses considerable challenges due to time and cost limitations. Currently, nucleic acid‐based tests are the only reliable method for diagnosing recent infections during the window period post‐infection and pre‐seroconver
Evaluation and application of reverse transcription loop-mediated isothermal amplification for detection of noroviruses
✍ Scribed by Tomoko Yoda; Yasuhiko Suzuki; Kenji Yamazaki; Naomi Sakon; Masashi Kanki; Ikuko Aoyama; Teizo Tsukamoto
- Publisher
- John Wiley and Sons
- Year
- 2007
- Tongue
- English
- Weight
- 213 KB
- Volume
- 79
- Category
- Article
- ISSN
- 0146-6615
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
A one‐step reverse transcription loop‐mediated isothermal amplification (RT‐LAMP) assay for the detection of norovirus (NV) was developed. In order to design primer sets for the detection of a wide range of NVs, NVs were categorized into three groups, that is, genogroup I (GI), prevalent GII, and minor GII; three sets of primers were developed for each group. Clinical specimens of patients suffering from enteric RNA viruses, such as NV, group A and C rotavirus, and sapovirus were examined using these primer sets. Various genotypes of NVs were detected in clinical specimens from patients infected with NV where no false positive reaction was observed with other enteric RNA viruses. Additionally, 88 samples of acute gastroenteritis outbreaks were analyzed by an RT‐LAMP assay and compared with the results of routine RT‐PCR. The results of the RT‐LAMP assay corresponded well to that of RT‐PCR. These findings suggest the practical application of the RT‐LAMP assay for the detection of NVs in clinical specimens. Consequently, the RT‐LAMP system and conventional detection kits (NVGI and NVGII detection kits; Eiken Chemical Co., Ltd., Japan) were compared. The detection rate of the prevalent and minor GII primer sets was similar to that of the conventional NVGII kit, while the detection rate of the GI primer set is different because it can detect several genotypes better than the conventional NVGI kit. This is an initial report that the RT‐LAMP system is able to detect NVs in clinical specimens within a wide range. J. Med. Virol. 79:326–334, 2007. © 2007 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract Two genetic diagnosis systems using reverse transcription‐loop‐mediated isothermal amplification (RT‐LAMP) technology were evaluated: one for detecting the HA gene of the pandemic influenza A/H1N1 2009 virus (H1pdm RT‐LAMP) and the other for detecting the matrix gene of the influenza A
## Abstract Annual seasonal outbreaks of respiratory syncytial virus (RSV) infection occur every winter. Most patients are diagnosed clinically by a rapid detection kit for RSV protein(s) from nasopharyngeal secretion (NPS), but some problems have been reported on the specificity and sensitivity of
## Abstract Norovirus is a major etiologic agent in worldwide outbreaks of gastroenteritis associated with food as well as person‐to‐person transmission. The ubiquitous nature of Norovirus necessitates simple and rapid detection methods with high accuracy and sensitivity. To this end, several inves
BACKGROUND: A loop-mediated isothermal amplification (LAMP) assay was developed for the rapid detection (within 2 h) of Alicyclobacillus acidoterrestris. The assay detected the species-specific DNA sequence of the 16S-23S rRNA internal transcribed spacer. ## RESULTS: The eight strains of A. acidot
## Abstract A new method was developed for detection of human papillomavirus (HPV) by loop‐mediated isothermal amplification (LAMP), which was compared with the polymerase chain reaction (PCR), and real‐time PCR for specificity and sensitivity. All initial validation studies with the control DNA pr