Establishing a pure lymphocyte gate for subset analysis by flow cytometry
โ Scribed by Joseph M. Horvatinovich; Sara D. Sparks; Karen P. Mann
- Publisher
- John Wiley and Sons
- Year
- 1996
- Tongue
- English
- Weight
- 549 KB
- Volume
- 26
- Category
- Article
- ISSN
- 0196-4763
No coin nor oath required. For personal study only.
โฆ Synopsis
Development of a more cost-effective and efficient method of performing lymphocyte subset analysis is of continuing importance in clinical flow cytometry laboratories. Current two-color methods utilize forward and right angle light scatter and multiple tubes per sample and are thereby liable to gate contamination. Methods using three-color analysis with CD45 vs. right angle light scatter ( R A N gating cannot always exclude a contaminating nonlymphoid population. We have established a two tube approach to directly measure total T cells, T suppressor, and T helper subsets, total B cells and total natural killer cells. The technique involves staining of whole blood with a mixture of five monoclonal antibodies conjugated to three fluorochromes: CD4+ CD19 fluorescein isothiocyanate (FITC), CD3 + CD33 phycoerythrin (PE), CD45 peridin chlorophyll alpha protein (PerCP), CD8+CD16 FITC, CD3+CD33 PE, and CD45 PerCP. Analysis is performed using a single laser flow cytometer. This method has equivalent recovery to and improved purity of the lymphocyte gate when compared to well-established methods. These antibody combinations additionally allow clear separation of lymphocytes from other leukocytes and debris as well as separation of the T cell helper and suppressor subsets, natural killer cells and B lymphocytes. We additionally provide preliminary data that an accurate lymphocyte subset analysis can be performed on a single tube containing five antibodies (CD4+ CD19 FITC, CD3 + CD33 PE, and CD45 PerCP), although some measurements are performed deductively. @ 1996 Wiley-Liss. Inc.
๐ SIMILAR VOLUMES
Current regulatory agencies specify the use of 2,500 gated lymphocytes for accurate lymphocyte immunophenotyping by flow cytometry. However, acquisition of 2,500 gated lymphocytes is often technically infeasible when testing whole blood from lymphopenic patients. Our laboratory thus compared CD3, CD
A microsample delivery system (MSDS) was tested for automatic flow cytometry (FCM) analysis of DNA synthesis in stimulated human peripheral blood lymphocytes (PBL) cultivated in wells of microtiter plates. After incubation, either for 1-3 days with phytohemagglutinin, concanavalin A, and pokeweed mi
## Abstract ## Background Immunophenotyping of whole blood (WB) and isolated peripheral blood mononuclear cells (PBMCs) is a common tool used to evaluate immune system changes in clinical studies. The development of methods that would allow preservation of samples for flow cytometric analysis is i