𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Error factors in quantitative total reflection x-ray fluorescence analysis

✍ Scribed by Yoshihiro Mori; Kenichi Uemura


Publisher
John Wiley and Sons
Year
1999
Tongue
English
Weight
116 KB
Volume
28
Category
Article
ISSN
0049-8246

No coin nor oath required. For personal study only.

✦ Synopsis


This paper reviews and discusses the error factors in quantitative total reflection x-ray fluorescence analysis, primarily with regard to the surface contamination of silicon wafers. The error factors were classified into three origins: instrumental, sample and data processing. The instrumental error factors originate from source x-ray stability, accuracy of the mechanical glancing angle, position accuracy of sample stage and spurious peaks from the detection system. The sample error factors arise from lateral and depth distribution of the analyte, surface roughness and diffraction of the primary x-rays. The data processing error factors are from interfering peaks and background definition. The accuracy and detection limit are affected by all the error sources listed above. Of these factors, the depth distribution of the analyte is the most important, because this factor is often overlooked and because it is difficult to control.


📜 SIMILAR VOLUMES


Development of total reflection x-ray fl
✍ Christina Streli 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 276 KB 👁 1 views

Total reflection x-ray fluorescence analysis (TXRF) has been developed systematically at the Atominstitute from 1974 continuously up to the present. It is now an internationally accepted and applied method of trace element analysis by energy-dispersive XRF in a special excitation mode competing with

Multi-element analysis of fine roots of
✍ Marie Olsson; Arturs Viksna; Heljä-Sisko Helmisaari 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 54 KB 👁 1 views

The aim of this work was to investigate whether total reflection x-ray fluorescence (TXRF) is a satisfactory technique for the determination of trace element concentrations in fine roots. Fine roots in diameter classes <1 and 1-2 mm from Scots pine (Pinus sylvestris L.) were used. The roots were col

Comparison between proton-induced x-ray
✍ J. A. Liendo; A. C. González; C. Castelli; J. Gómez; J. Jiménez; L. Marcó; L. Sa 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 124 KB 👁 2 views

A comparison between use of proton-induced x-ray emission (PIXE) and total reÑection x-ray Ñuorescence (TXRF) techniques in relation to the elemental analysis of amniotic Ñuid (AF) was carried out by measuring the concentrations of Cl, K, Ca, Fe, Cu, Zn and Br. For 10 AF samples analyzed, the agreem

Total Reflection X-Ray Fluorescence Anal
✍ R. Görgl; P. Wobrauschek; P. Kregsamer; Ch. Streli; M. Haller; A. Knöchel; M. Ra 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 341 KB 👁 2 views

The use of synchrotron radiation as the excitation source for total reÑection x-ray Ñuorescence analysis (SR-TXRF) in combination with a multilayer structure for monochromatization led to detection limits in the femtogram range for medium-Z elements. Experiments were performed at the Hasylab Beamlin

Determination of Trace Elements in Miner
✍ P. Kump; M. Nečemer; M. Veber 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 234 KB 👁 1 views

The determination of trace elements in mineral water by preconcentration with ammonium pyrrolidinedithiocarbamate (APDC) is described. Samples were spiked with an internal Ga standard and the precipitated dithiocarbamates of trace elements were separated by Ðltration through a Nuclepore Ðlter. A sma