Endorectal coil MR imaging findings in hemospermia
โ Scribed by Lencioni, R
- Publisher
- Springer
- Year
- 1999
- Tongue
- English
- Weight
- 816 KB
- Volume
- 8
- Category
- Article
- ISSN
- 0968-5243
No coin nor oath required. For personal study only.
โฆ Synopsis
The purpose of this study was to illustrate the spectrum of abnormalities found at endorectal coil magnetic resonance (MR) imaging in patients with hemospermia. Ninety patients aged between 23 and 71 years (mean age 41 years) presenting with hemospermia underwent evaluation with endorectal coil MR imaging at 1.5 T. Duration of hemospermia ranged between 5 days and 4 years (mean 15 months). MR examination protocol included T1-weighted spin-echo (SE) and T2-weighted fast SE MR images obtained in the sagittal, coronal, and axial planes. Abnormalities were observed on endorectal-coil MR images in 49 of 90 patients (54%). Blood within the seminal vesicle or the ejaculatory duct was recognized in 23 of 90 patients (25%). Dilatation of the seminal vesicles or the ejaculatory duct was observed in 31 of 90 patients (34%). Cystic lesions were identified in 14 cases, eight of which involved the utriculus and six the ejaculatory duct. Calculi within the seminal vesicles were depicted in seven patients. No malignant disease was demonstrated. In conclusion, despite the evidence that hemospermia is most often a benign and self-limiting condition, we found that endorectal coil MR imaging can detect abnormal findings in more than half of the patients, and may be helpful in assessing the level at which hemorrhage occurred and in defining the cause of the disease.
๐ SIMILAR VOLUMES
## Abstract The value of inversionโrecovery (IR) sequences in the diagnosis and staging of prostatic carcinoma with magnetic resonance (MR) imaging was studied. Twentyโsix patients with carcinoma of the prostate were imaged at 1.5 T with an endorectal surface coil and with a variety of IR sequences
## Abstract ## Purpose To demonstrate the feasibility of using a double loop phased array endorectal coil combined with a phased array body coil to image the prostate at 3T. ## Materials and Methods We designed and constructed a novel prostate coil employing two arrayed 4.0 ร 5.0 cm loops, tuned
## Abstract ## Purpose: To develop and validate a postโprocessing correction algorithm to remove the effect of the inhomogeneous reception profile of the endorectal coil on MR spectroscopic imaging (MRSI) data. ## Materials and Methods: A postโprocessing algorithm to correct for the endorectal c