๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Endorectal coil MR imaging findings in hemospermia

โœ Scribed by Lencioni, R


Publisher
Springer
Year
1999
Tongue
English
Weight
816 KB
Volume
8
Category
Article
ISSN
0968-5243

No coin nor oath required. For personal study only.

โœฆ Synopsis


The purpose of this study was to illustrate the spectrum of abnormalities found at endorectal coil magnetic resonance (MR) imaging in patients with hemospermia. Ninety patients aged between 23 and 71 years (mean age 41 years) presenting with hemospermia underwent evaluation with endorectal coil MR imaging at 1.5 T. Duration of hemospermia ranged between 5 days and 4 years (mean 15 months). MR examination protocol included T1-weighted spin-echo (SE) and T2-weighted fast SE MR images obtained in the sagittal, coronal, and axial planes. Abnormalities were observed on endorectal-coil MR images in 49 of 90 patients (54%). Blood within the seminal vesicle or the ejaculatory duct was recognized in 23 of 90 patients (25%). Dilatation of the seminal vesicles or the ejaculatory duct was observed in 31 of 90 patients (34%). Cystic lesions were identified in 14 cases, eight of which involved the utriculus and six the ejaculatory duct. Calculi within the seminal vesicles were depicted in seven patients. No malignant disease was demonstrated. In conclusion, despite the evidence that hemospermia is most often a benign and self-limiting condition, we found that endorectal coil MR imaging can detect abnormal findings in more than half of the patients, and may be helpful in assessing the level at which hemorrhage occurred and in defining the cause of the disease.


๐Ÿ“œ SIMILAR VOLUMES


Endorectal surface coil MR imaging of pr
โœ Farhad Parivar; Vasanthan Rajanayagam; Victor Waluch; Ross T. Eto; Lawrence W. J ๐Ÿ“‚ Article ๐Ÿ“… 1991 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 855 KB

## Abstract The value of inversionโ€recovery (IR) sequences in the diagnosis and staging of prostatic carcinoma with magnetic resonance (MR) imaging was studied. Twentyโ€six patients with carcinoma of the prostate were imaged at 1.5 T with an endorectal surface coil and with a variety of IR sequences

Prostate MR imaging at 3T with a longitu
โœ David Y. Kim; Mitchell D. Schnall; Mark A. Rosen; Thomas Connick ๐Ÿ“‚ Article ๐Ÿ“… 2008 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 239 KB

## Abstract ## Purpose To demonstrate the feasibility of using a double loop phased array endorectal coil combined with a phased array body coil to image the prostate at 3T. ## Materials and Methods We designed and constructed a novel prostate coil employing two arrayed 4.0 ร— 5.0 cm loops, tuned

Post-processing correction of the endore
โœ Susan M. Noworolski; Galen D. Reed; John Kurhanewicz; Daniel B. Vigneron ๐Ÿ“‚ Article ๐Ÿ“… 2010 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 684 KB

## Abstract ## Purpose: To develop and validate a postโ€processing correction algorithm to remove the effect of the inhomogeneous reception profile of the endorectal coil on MR spectroscopic imaging (MRSI) data. ## Materials and Methods: A postโ€processing algorithm to correct for the endorectal c

MR imaging findings in hibernoma
โœ S. Peer; R. Kรผhberger; A. Dessl; W. Judmaier ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› Springer ๐ŸŒ English โš– 17 KB