Enantiomeric separation of chiral pesticides by high-performance liquid chromatography on an amylose tris-(S)-1-phenylethylcarbamate chiral stationary phase Amylose tris-(S)-1-phenylethylcarbamate chiral stationary phase (CSP) was prepared. The direct enantiomeric separation of chiral pesticides on
Enantiomeric separation of chiral pesticides by high performance liquid chromatography on cellulose tris-3,5-dimethyl carbamate stationary phase under reversed phase conditions
✍ Scribed by Qin Tian; Chunguang Lv; Peng Wang; Liping Ren; Jing Qiu; Li Li; Zhiqiang Zhou
- Publisher
- John Wiley and Sons
- Year
- 2007
- Tongue
- English
- Weight
- 757 KB
- Volume
- 30
- Category
- Article
- ISSN
- 1615-9306
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Twenty chiral pesticides were tested, of which seven samples were directly separated by HPLC using cellulose tris‐3,5‐dimethyl carbamate (CDMPC) chiral stationary phase under RP conditions. The influence of mobile phase composition and column temperatures from 0°C to 40°C on the separations were investigated. The mobile phases were methanol/water or ACN/water at a flow rate of 0.8 mL/min with UV detection at 230 or 210 nm. Epoxiconazole, terallethrin, benalaxyl, and diclofop‐methyl were observed to obtain the baseline separation under suitable conditions and other pesticides pyriproxyfen, lactofen, and quizalofop‐ethyl were separated partially. The retention factors (k) and selectivity factor (α) for the enantiomers of most investigated pesticides decreased upon increasing the temperature except for the selectivity factors (α) of pyriproxyfen in methanol/water. The ln α–1/T plots for racemic chiral pesticides were linear at the range of 0–40 except for that of pyriproxyfen enantiomers in methanol/water and the chiral separations were controlled by enthalpy. Better separations were not always at low temperature. The elution orders of the eluting enantiomers were determined by a circular dichroism (CD) detector.
📜 SIMILAR VOLUMES
## Abstract Direct optical resolution of five novel tetrahedral heterometal cluster enantiomers has been achieved for the first time on a cellulose tris‐(3,5‐dimethylphenylcarbamate) chiral stationary phase, using hexane as the mobile phase with various alcohols as modifiers. UV detection was carri
## Abstract This study used chiral columns packed with 3‐μm and 5‐μm particles to comparatively separate enantiomers of 9 triazole fungicides, and Lux Cellulose‐1 columns with chiral stationary phase of cellulose‐__tris__‐(3,5‐dimethylphenylcarbamate) were used on reverse‐phase high‐performance liq