๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Elimination of interfering substances in the presence of detergent in the bicinchoninic acid protein assay

โœ Scribed by Ronald E. Gates


Publisher
Elsevier Science
Year
1991
Tongue
English
Weight
749 KB
Volume
196
Category
Article
ISSN
0003-2697

No coin nor oath required. For personal study only.

โœฆ Synopsis


Substantial time and effort are necessary to eliminate interference due to thiols and reducing sugars in the bicinchoninic acid protein assay when detergents such as sodium dodecyl sulfate (SDS) are present. A method to eliminate these interfering substances based on the binding of proteins to positively charged nylon membranes at pH 8.5 followed by methanol and aqueous washes is described. Color development using bicinchoninic acid occurs in solution with only a minor contribution from the nylon membrane itself. The retention of most proteins on the membrane is nearly quantitative and is only slightly decreased by high salt or detergent in the assay mixture. The interference due to thiol compounds such as beta-mercaptoethanol and dithiothreitol is completely eliminated while that due to reducing sugars such as glucose is substantially reduced. Therefore, the amount of protein dissolved in the sample buffer used for SDS-polyacrylamide gel electrophoresis (2% SDS and 5% beta-mercaptoethanol) can be determined with this bound protein assay.


๐Ÿ“œ SIMILAR VOLUMES


Modification of the bicinchoninic acid p
โœ Richard E. Morton; Tracy A. Evans ๐Ÿ“‚ Article ๐Ÿ“… 1992 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 356 KB

The bicinchoninic acid (BCA) assay method for the determination of protein has been investigated for its utility in measuring the protein content of plasma lipoproteins. Although other methods, principally those based on the method of Lowry et al. (1951, J. Biol. Chem. 193, 265-275) have been extens

Potential interference of hydrogen perox
โœ W.L. Baker ๐Ÿ“‚ Article ๐Ÿ“… 1991 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 221 KB

At a concentration of 20-800 nmol/0.1 ml hydrogen peroxide instantly reacts with a 2,2'-bicinchoninic acid copper color reagent. It also reacts with a reformulated reagent at pH 7 but the color develops less rapidly. While the effect may interfere with protein estimations at alkaline pH, the effect

A one-step biuret assay for protein in t
โœ Christopher Watters ๐Ÿ“‚ Article ๐Ÿ“… 1978 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 200 KB

An alkaline-copper reagent is described which forms a soluble, stable complex with protein in the presence of detergent. The modified reagent produces a relatively uniform absorbance for six different proteins, and it may be used to determine the protein content of such heterogeneous samples as plas

How accurate is glucose analysis in the
โœ Renu Jain; Thomas F. Myers; Stephen E. Kahn; W. Patrick Zeller ๐Ÿ“‚ Article ๐Ÿ“… 1996 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 345 KB ๐Ÿ‘ 2 views

Whole blood glucose testing by reagent sticks is inaccurate at low plasma glucose concentrations and with varying hematocrit. Both conditions are frequently seen in newborn infants. Therefore plasma glucose analysis is the preferred method for newborn glucose monitoring. We encountered unanticipated