In the past 5 years radiofrequency personal exposure meters have been used to characterize the exposure during daily activities. We found from calibration tests for the 12 frequency bands of the EME Spy 121 exposimeter in a Gigahertz Transverse Electromagnetic cell and an Open Area Test Site, that t
Electromagnetic field measurements of radio transmitters in urban area and exposure analysis
✍ Scribed by Sukru Ozen; Selcuk Helhel; O. Halil Colak
- Publisher
- John Wiley and Sons
- Year
- 2007
- Tongue
- English
- Weight
- 702 KB
- Volume
- 49
- Category
- Article
- ISSN
- 0895-2477
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Far field measurement of electric fields in an area surrounding the GSM, and TV broadcast stations in Antalya (Turkey) is presented. A great inclination to use of mobile phones as well as FM radios and TV transmitters has brought about a proliferation of new radio base stations. Lack of public information and scientific studies carried out at limit values cause a spite against radio companies. Collected data through out Antalya City demonstrates that radio emissions are about at most 10% of limit values for GSM transmitters, while it is about 50% of limit values for TV transmitters. Results show that 164 MHz radio transmitter (∼1.1 mW/kg) produces about 60 times stronger local SAR than 1800 MHz GSM transmitter (∼0.02 mW/kg), and children are more sensitive than average‐man for the same electric field intensity, and gather more SAR values.© 2007 Wiley Periodicals, Inc. Microwave Opt Technol Lett 49: 1572–1578, 2007; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.22548
📜 SIMILAR VOLUMES
## Abstract In two previous studies we demonstrated that radiofrequency electromagnetic fields (RF EMF) similar to those emitted by digital radiotelephone handsets affect brain physiology of healthy young subjects exposed to RF EMF (900 MHz; spatial peak specific absorption rate [SAR] 1 W/kg) eithe
## Abstract In this work, a combination of the physical optics in the time domain (TDPO) method and a time‐domain version of the equivalent currents of the physical theory of diffraction (TDPTD) with the finite‐difference time‐domain method (FDTD) is presented in order to compute scattered fields b
## Abstract ## Purpose To determine if magnetic field exposure close to two clinical 1.5T magnetic resonance imaging (MRI) scanners during image acquisition and when moving in the spatially‐varying static magnetic field is compliant with European Union (EU) Directive 2004/40/EC (the Directive). #