✦ Synopsis


During the electrochemical preparation of perborate in carbonate-borate solutions, peroxocarbonate (CIOBB-) is formed at the platinum anode; this CaOa%-hydrolyses to HIOs in the solution. The factors affecting the current efficiency Ra at [HIO,l = 0 were investigated. The R/ [l&O,] relation and the ~/fog J curve were measured under various conditions. olation of the R/[HnO,l curve, R, was determined. By linear extrap-R, strongly increases with increasing cd until 200 mA/cma and slightly decreases above 400 mA/ cm2. Furthermore R. increases by replacing Na+ by K+ , with increasing carbonate concentration, with decreasing temperature, by rotation of the anode and by addition of fluoride at 100 mA/cma; fluoride has no influence at 400 mA/cma. The pH has no effect on R,, in the region from 9 to 12. At higher pH a strong decrease of R. occurs. Kinetic factors determine R. at current densities lower than 75 mA/cm*. current density Jo of the reaction The standard exchange 2 COsa-= CBO,*-+ 2 e is smaller than 1.5 x 1O-8 A/cm* and the transfer coefficient a is 0.3. At cd > 350 mA/cme peroxocarbonate formation is limited by diffusion of carbonate. The diffusion coefficients of carbonate ions in 1.25 M NaaCOs and 1.25 M KBCOs are respectively 2.8 x 10~~ and 3.6 x 1O-e cm*/s. R&m&Pendant la preparation Blectrochimique de perborate en milieu carbonate-borate, du peroxocarbonate (C%Osa-) est form6 sur l'anode de platine; ce C,O,a-hydrolyse & HsOp dans la solution. Les facteurs tiuant le rendement du courant R, A [H,O,] = 0 ont Btb &udi&. C'est pourquoi la relation R/[H,O,] et la courbe e/log J ont 6tb mesur&es dans des circonstances variees. R,, ktait determink par extrapolation linkire de la courbe R/[H808]. Nous avons trouv6 que R. augmente fortement en augmentant la densit de courant jusqu'h 200 mA/cmB et que R. diminue un peu en plus de 400 mA/cmP. D'alleirs nous augrnentons R. en remplapnt Na+ par K+, en augmentant la concentration du carbonate et en diminuant la temp&ature, en faisant toumer l'anode et par addition de fluorure a 100 mA/cmB; de la fluorure ne l'enfluence pas & 400 mA/cm*. Le pH ne provoque pas le R. dans la rkgion de 9 & 12. Quand le pH monte plus, & diminue fortement. Des resultats de la recherche nous avons d&iv6 que des facteurs cin&iques determinent R. ii des densites de courant moins de 75 mA/cm2. La den&t de courant d'kchange J,, de la r&action 2 COsa-,' C,O,a-+ 2 e est plus petite que 1,5 x lo-* A/cm2 et le coefficient de transfert a est 0,3. A des densitb de courant plus hautes que 350 mA/crna, la formation de peroxocarbonate est limit& par la diffusion de carbonate. Les coefficients de diffusion d'ions de carbonate en milieu I,25 M Na,CO, et 1,25 M K&O, sont respectivement 2,8 x 10-O et 3,6 x 1O-6 cm'+. Zusammenfassung-WSihrend der elektrochemischen Herstellung von Perborat in Karbonat-Borat Ltisungen wird an der Pt-Anode Peroxokarbonat Ca0,,2-gebildet; dat CaOl*-hydrolysiert im Elektrolyten zu HaOe. Es wurden die Faktoren untersucht welche die Stromausbeute R, bei [H*O,] = 0 beeitiussen. Zu dem Zweck wurden die R,/[H,Oa] Beziehung und die ~/log JKurve unter wechselnden Bedingungen gemessen. Durch lineare Extrapolation der R/[H,O,] Kurve wurde R,, ermittelt. Es wurde gefunden dass R,, stark zunimmt mit wachsender Stromdichte bis zu 200 mA/cmP urn oberhalb 400 mA/cn? wieder ein wenig abzufallen. Ferner nimmt R. zu wenn man Na+ durch K+ ersetzt, die Karbonatkonzentration erhijht, die Temperatur erniedrigt, die Anode rotiert und bei 100 mA/crna Fluoride zusetzt; Fluoride sind unwirksam bei 400 mA/cm8. Der pH-Wert im Bereich von 9-12 beeinflusst R. nicht. Bei hSheren pH-Werten nimmt R, stark ab. Aus diesen Ergebnissen wurde geschIossen dass kinetische Faktoren & bestimmen bei Stromdichten unterhalb 75 mA/cn?. Die Standardaustauschstromdichte J0 der Reaktion 2 CO,"-; C,Oaa--t-2 e * Manuscript received


📜 SIMILAR VOLUMES


The electrolysis of a carbonate-borate s
✍ P.M.v.d. Wiel; L.J.J. Janssen; J.G. Hoogland 📂 Article 📅 1971 🏛 Elsevier Science 🌐 English ⚖ 533 KB

The current efficiency R (corrected for the chemical disproportionation of HtOI in the bulk of electrolyte) of the electrolytic formation of perborate decreases with increasing concentration of H801d\_ The factors causing this decrease were investigated. The relation between R and [H,O,] and the dif

Electrolysis of an acidic NaCl solution
✍ L.J.J. Janssen; J.G. Hoogland 📂 Article 📅 1970 🏛 Elsevier Science 🌐 English ⚖ 672 KB

During electrolysis of an acid chloride solution, atomic chlorine is taken up by a graphite anode. After switching off the current the evolution of molecular chlorine continues. This phenomenon we call residual gas evolution (r.g.e.) It is established that the molecular chlorine is formed according