## Abstract The aims of this study were to investigate the effects of Zr addition and potentiodynamic polarization on the microstructure and corrosion resistance of Tiβ22Nb and Tiβ22Nbβ6Zr alloy samples. The corrosion tests were carried out in 0.9% NaCl at 37βΒ°C and neutral pH value, utilizing the
Electrochemical impedance spectroscopic studies of titanium and its alloys in saline medium
β Scribed by S. Tamilselvi; R. Murugaraj; N. Rajendran
- Publisher
- John Wiley and Sons
- Year
- 2007
- Tongue
- German
- Weight
- 355 KB
- Volume
- 58
- Category
- Article
- ISSN
- 0947-5117
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
The influence of potential on electrochemical behaviour of pure Ti, Tiβ6Alβ7Nb, and Tiβ6Alβ4V ELI alloy under saline conditions were investigated by electrochemical impedance spectroscopy (EIS). All measurements were carried out in saline solution (0.9% NaCl) at different impressed potentials (corrosion potential (E~corr~), 0 mV (SCE) and + 500 mV (SCE)) for 1 h. The experimental results were compared with those obtained by potentiodynamic polarization curves. The corrosion current densities obtained for the titanium alloys showed lower values than for pure Ti, indicating the formation of a stable passive film with time. Electrochemical impedance spectroscopic studies indicated that the resistance of the passive film increased with the impressed potential. The impedance spectra were fitted using a nonβlinear least square (NLLS) fitting procedure. The magnitude of the corrosion resistance of titanium alloys under saline solution was compared and results are presented.
π SIMILAR VOLUMES
## Abstract The measurement of electrochemical impedance is a valuable tool to assess the electrochemical environment that exists at the surface of metallic biomaterials. This article describes the development and validation of a new technique, potential step impedance analysis (PSIA), to assess th
## Abstract The exfoliation corrosion susceptibility and electrochemical impedance spectroscopy (EIS) of 7150 Al alloys with T6, T73, and RRA (retrogression at 175βΒ°C for 3 h) tempers in EXCO solution were investigated. The anodic equilibrium precipitate __Ξ·__(MgZn~2~) is continuous or closely spac
The initiation and propagation characteristics of the exfoliation corrosion (EC) of 2090-T6 Al-Li alloy in EXCO solution has been studied using electrochemistry impedance spectroscopy (EIS), electrochemical noise (EN), and optical microscope techniques. A four-stage evolution of localized corrosion