## Abstract In this investigation the electrochemical behaviour of the Ti‐13Nb‐13Zr, Ti‐6Al‐4V and Ti‐6Al‐7Nb alloys, for application as implant materials was evaluated in Hanks' solution by electrochemical techniques. The alloys were immersed in this solution for 410 days and periodically they wer
Electrochemical corrosion behavior of biomedical Ti–22Nb and Ti–22Nb–6Zr alloys in saline medium
✍ Scribed by B. L. Wang; Y. F. Zheng; L. C. Zhao
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- German
- Weight
- 527 KB
- Volume
- 60
- Category
- Article
- ISSN
- 0947-5117
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The aims of this study were to investigate the effects of Zr addition and potentiodynamic polarization on the microstructure and corrosion resistance of Ti–22Nb and Ti–22Nb–6Zr alloy samples. The corrosion tests were carried out in 0.9% NaCl at 37 °C and neutral pH value, utilizing the OCP, potentiodynamic polarization, and electrochemical impedance spectroscopy (EIS) techniques. The results of XRD and optical microscopy indicated that the addition of Zr stabilized the β phase, which plays a crucial role in the corrosion resistance improvement of the Ti–22Nb–6Zr alloy. From the polarization curves, it can be seen that the alloys exhibited a wide passive region without the breakdown of the passive films and also low corrosion current densities. In addition, the values of the corrosion current densities and passive current densities decreased with the addition of 6 at% Zr into the Ti–22Nb alloy. The EIS results of these two alloy samples after 1‐h immersion in 0.9% NaCl solution, and being fitted by R~S~(Q~P~R~P~) model, suggested that the corrosion resistance of the passive films improved with the addition of Zr and only a single passive film formed on the surfaces. However, two time constants were observed for the Ti–22Nb and Ti–22Nb–6Zr alloy samples after potentiodynamic polarization, the spectra of which can be fitted using the R~s~(Q~o~(R~o~(Q~b~R~b~))) model. In addition, the corrosion resistance of the two alloy samples was reinforced significantly because of polarization when compared to the immersed samples. All these observations suggested a nobler electrochemical behavior of the titanium alloys with the addition of Zr element and after polarization.
📜 SIMILAR VOLUMES
## Abstract The aim of this study was to investigate the effects of Hf content and immersion time on the electrochemical corrosion behavior of the Ti‐22Nb‐__x__Hf (__x__ = 0, 2, 4, and 6 at%) alloy samples in 0.9% NaCl solution at 37 °C and neutral pH range, utilizing the potentiodynamic polarizati
## Abstract There is much discussion about the toxic effect of vanadium and aluminum contained in Ti6Al4V alloy for prosthetic implants. The goal of the present investigation was to develop new titanium alloys with sufficient mechanical properties using more biocompatible alloying elements: zirco
The electrochemical behavior of Ti-6Al-7Nb alloy with and without plasma-sprayed hydroxyapatite (HA) coating was investigated in Hank's balanced salt solution at 37 degrees C. This behavior was evaluated by analyzing both corrosion potential variation with time curves and potentiodynamic polarizatio
## Abstract The corrosion behavior of Ti–5Ag–xFe alloys (x = 1, 2.5, 5 wt%) in neutral saline solution was investigated by the open‐circuit potential (OCP), potentiodynamic polarization, electrochemical impedance spectroscopy (EIS), and potentiostatic tests. The microstructural observation indicate
## Abstract In this study, the __in vitro__ corrosion resistance of a superferritic stainless steel in naturally aerated Hank's solution at 37°C has been determined to evaluate the steel for use as a biomaterial. The potentiodynamic polarization method and electrochemical impedance spectroscopy (EI