𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Electrochemical aspects of Ti–Ta alloys in HBSS

✍ Scribed by D. Mareci; R. Chelariu; G. Ciurescu; D. Sutiman; T. Gloriant


Publisher
John Wiley and Sons
Year
2010
Tongue
German
Weight
566 KB
Volume
61
Category
Article
ISSN
0947-5117

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Corrosion behaviour of the studied Ti–Ta alloys with Ta contents of 30, 40 and 50 wt% together with the currently used metallic biomaterials commercial pure titanium (Cp–Ti) was investigated for biomedical applications. All the samples were tested by potentiodynamic polarization curves and electrochemical impedance spectroscopy (EIS) in Hank's balanced salt solution (HBSS) with and without albumin protein at 25 °C. Very low corrosion current densities and passive current densities (in the order of 10^−6^ A/cm^2^) were obtained from the polarization curves, indicating a typical passive behaviour for all the samples in HBSS with and without albumin. The EIS technique was applied to study the nature of the passive film formed on all the samples at various imposed potentials −500 mV (SCE), 0 mV (SCE), 500 mV (SCE) and 1000 mV (SCE). The equivalent circuit (EC) used successfully to describe the behaviour of the samples suggests a single passive film present on the metals' surface in HBSS with and without albumin. The results showed that the presence of albumin in HBSS had an influence on the zero current potential (ZCP), polarization resistance (R~p~) and capacitance (C). The presence of albumin protein in HBSS improved slightly the corrosion resistance of the entire sample. The experimental results confirm that the electrochemical behaviour of the studied Ti–Ta alloys is better to that of Cp–Ti, suggesting their promising potential for biomedical applications.


📜 SIMILAR VOLUMES


In vitro biocompatibility, mechanical pr
✍ Ito, Atsuo ;Okazaki, Yoshimitsu ;Tateishi, Tetsuya ;Ito, Yoshimasa 📂 Article 📅 1995 🏛 John Wiley and Sons 🌐 English ⚖ 746 KB

## Abstract There is much discussion about the toxic effect of vanadium and aluminum contained in Ti6Al4V alloy for prosthetic implants. The goal of the present investigation was to develop new titanium alloys with sufficient mechanical properties using more biocompatible alloying elements: zirco

Electrochemical corrosion behavior of bi
✍ B. L. Wang; Y. F. Zheng; L. C. Zhao 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 German ⚖ 527 KB

## Abstract The aims of this study were to investigate the effects of Zr addition and potentiodynamic polarization on the microstructure and corrosion resistance of Ti–22Nb and Ti–22Nb–6Zr alloy samples. The corrosion tests were carried out in 0.9% NaCl at 37 °C and neutral pH value, utilizing the

Cytocompatibility and electrochemical pr
✍ Keun-Taek Oh; Dong-Kuk Kang; Good-Sun Choi; Kyoung-Nam Kim 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 409 KB

## Abstract The purpose of this study was to develop Ti–Au alloys with a higher resistant to corrosion, better biocompatibility, and better mechanical properties than the commercially pure titanium and its alloys. Ti–Au alloys were designed with a gold content that ranged from 0 to 5.0 at % in step

Corrosion resistance of the new Ti-25Ta-
✍ E. Vasilescu; P. Drob; C. Vasilescu; S. I. Drob; E. Bertrand; D. M. Gordin; T. G 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 German ⚖ 675 KB

## Abstract In this study, a new Ti‐25Ta‐25Nb (mass%) β alloy was synthesised by cold crucible semi‐levitation melting. After melting, each ingot was solution treated in the β‐phase domain and water quenched in order to obtain a fully recrystallised homogeneous β‐phase microstructure. To evaluate t