𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Effects of variation in modulator temperature during cryogenic modulation in comprehensive two-dimensional gas chromatography

✍ Scribed by Frédéric Begnaud; Christian Debonneville; Jean-Pierre Probst; Alain Chaintreau; Paul D. Morrison; Jacqui L. Adcock; Philip J. Marriott


Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
1010 KB
Volume
32
Category
Article
ISSN
1615-9306

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Many modulation systems in comprehensive 2D GC (GC×GC) are based on cryogenic methods. High trapping temperatures in these systems can result in ineffective trapping of the more volatile compounds, whilst temperatures that are too low can prevent efficient remobilisation of some compounds. To better understand the trapping and release of compounds over a wide range of volatilities, we have investigated a number of different constant temperature modulator settings, and have also examined a constant temperature differential between the cryo‐trap and the chromatographic oven. These investigations have led us to modify the temperature regulation capabilities of the longitudinally modulated cryogenic system (LMCS). In contrast to the current system, where the user sets a constant temperature for the cooling chamber, the user now sets the temperature difference between the cryo‐trap and the chromatographic oven. In this configuration, the cooling chamber temperature increases during the chromatographic run, tracking the oven temperature ramp. This produces more efficient, volatility‐dependent modulation, and increases the range of volatile compounds that can be analysed under optimal trap‐and‐release conditions within a single analytical run. This system also reduces cryogenic fluid consumption.


📜 SIMILAR VOLUMES


Temperature requirements for thermal mod
✍ Richard B. Gaines; Glenn S. Frysinger 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 768 KB

## Abstract Temperature requirements for trapping and release of compounds in a cryogenic gas loop‐type GC×GC modulator were determined. Maximum trapping temperatures on the uncoated, deactivated modulator capillary were determined for compounds from C~4~ (bp –0.5°C) to C~40~ (bp 522°C). The liquid

Moving cryogenic modulator for the compr
✍ Jan Beens; Jens Dallüge; Mohamed Adahchour; René J. J. Vreuls; Udo A. Th. Brinkm 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 133 KB

## Abstract The modulation system in a comprehensive two‐dimensional gas chromatograph (GC×GC) can be regarded to be the heart of the analyzer. Different ways of modulating the effluent of the first column into very narrow pulses and injecting these onto the fast second column have been demonstrate

A comparison of modulating interface tec
✍ Andrew L. Lee; Alastair C. Lewis; Keith D. Bartle; James B. McQuaid; Philip J. M 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 386 KB 👁 2 views

Comprehensive two-dimensional gas chromatography GC = GC is a multidimensional method where the entire sample of interest undergoes chromatographic analysis via orthogonal coupling of two serially connected capillary columns, with selectivities of each dimension both independent and unique. The meth

Effects of pressure drop on absolute ret
✍ Robert Shellie; Philip Marriott; Paul Morrison; Luigi Mondello 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 238 KB

## Abstract Comprehensive two‐dimensional gas chromatography (GC×GC) analysis has the capability to resolve many more components of complex mixtures than traditional single column GC analysis. There is an increasing need to provide reliable identification of these separated components; time‐of‐flig