Moving cryogenic modulator for the comprehensive two-dimensional gas chromatography (GC×GC) of surface water contaminants

✍ Scribed by Jan Beens; Jens Dallüge; Mohamed Adahchour; René J. J. Vreuls; Udo A. Th. Brinkman


Publisher
John Wiley and Sons
Year
2001
Tongue
English
Weight
133 KB
Volume
13
Category
Article
ISSN
1040-7685

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The modulation system in a comprehensive two‐dimensional gas chromatograph (GC×GC) can be regarded to be the heart of the analyzer. Different ways of modulating the effluent of the first column into very narrow pulses and injecting these onto the fast second column have been demonstrated. Modulation can be established by applying heat, as in the first existing types of modulators, the two‐stage heated modulator and the Sweeper system. It can also be performed by applying cooling, as was demonstrated in the “longitudinally modulated cryogenic system.” Cryogenic systems have mechanical and applicational advantages over heated systems, as they are easier to install and maintain and do not need positive temperature differences to remobilize the analytes. A homemade moving cryogenic modulator was evaluated for use in a GC×GC system for the separation of (very) polar and nonpolar surface water contaminants. The results demonstrate that the performance of this less complex modulator is very comparable to the earlier reported types of modulators. It is further demonstrated that GC×GC is a very suitable technique to fully separate complex mixtures, such as surface water contaminants. The obtained separation appeared to be complete and peak identification was facilitated. © 2001 John Wiley & Sons, Inc. J Micro Sep 13: 134–140, 2001


📜 SIMILAR VOLUMES


A comparison of modulating interface tec
✍ Andrew L. Lee; Alastair C. Lewis; Keith D. Bartle; James B. McQuaid; Philip J. M 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 386 KB 👁 2 views

Comprehensive two-dimensional gas chromatography GC = GC is a multidimensional method where the entire sample of interest undergoes chromatographic analysis via orthogonal coupling of two serially connected capillary columns, with selectivities of each dimension both independent and unique. The meth

Proper Tuning of Comprehensive Two-Dimen
✍ Beens, Jan ;Blomberg, Jan ;Schoenmakers, Peter J. 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 152 KB 👁 2 views

Comprehensive two-dimensional gas chromatography (GC6GC) is an utterly suitable separation technique for the analysis of complex samples, such as oil fractions. Once the two columns and the operating conditions are properly tuned, the technique is able to provide a detailed characterization of such