𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Effects of skin temperature on lesion size in fractional photothermolysis

✍ Scribed by Hans Laubach; Henry H. Chan; Francisca Rius; R. Rox Anderson; Dieter Manstein


Publisher
John Wiley and Sons
Year
2007
Tongue
English
Weight
193 KB
Volume
39
Category
Article
ISSN
0196-8092

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Background and Objectives

Fractional photothermolysis is a new concept in cutaneous re‐modeling whereby laser‐induced microscopic zones of thermal injury (MTZ—Microscopic Treatment Zones) are surrounded by normal, viable tissue. This unique thermal damage pattern allows re‐epithelialization in less than 24 hours. To increase patient comfort level during the procedure of fractional photothermolysis, simultaneous skin cooling has been proposed and is now extensively used. The purpose of this in vitro study was to examine the influence of skin temperature on the diameter of the epidermal microthermal zone and the extent of thermal injury per unit area. The determination of the changes in these parameters that are due to skin temperature will allow the better control and understanding of fractional photothermolysis at different skin temperatures.

Materials and Methods

Fractional photothermolysis was performed with a 1,550 nm fiber laser (Fraxel SR® Laser) with 10 mJ per pulse on full‐thickness cadaver skin. The skin samples were brought prior to exposure to temperatures that ranged from 0 to 45°C. The epidermis of the skin samples was separated by dispase treatment, stained for thermal damage by NBTC stain, and lesion diameter was assessed by a blinded investigator.

Results

The average MTZ diameter exhibits a positive, linear relationship with skin temperature (R^2^ = 0.904, P < 0.0001). As the skin temperature increases from 0 to 45°C. The MTZ diameter increases from 93 to 147 µm (58%), and the MTZ area from 6,870 to 17,050 µm^2^ (148%).

Conclusion

The skin temperature affects the size of epidermal MTZs during fractional photothermolysis and is an important variable factor. The use of simultaneous skin cooling increases patient comfort; however, as it also decreases MTZ size, it may interfere with treatment efficacy. The control of skin temperature is necessary to provide a consistent outcome and to be able to compare treatments. Lasers Surg. Med. 39:14–18, 2007. © 2007 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


The effect of temperature on tyrosinase
✍ Kidson, S. H. ;Fabian, B. C. 📂 Article 📅 1981 🏛 John Wiley and Sons 🌐 English

## Abstract The tyrosinase activity of Himalayan mouse skin homogenates was measured over a range of temperatures using two sensitive radiometric assays—namely, (1) the measurement of ^14^C‐tyrosine incorporation into melanin, and (2) the measurement of ^3^HOH released as a by‐product of ^3^H‐tyros

Effect of temperature on particle separa
✍ Myeong Hee Moon; Kyung Hyun Lee; Byung Ryul Min 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 128 KB 👁 2 views

Hollow fiber flow field-flow fractionation HF-FlFFF has been tested Ž . by varying the temperature 21᎐73ЊC to increase separation speed with reduced lift forces. It has been experimentally shown that the separation time of 0.050᎐0.426-m polystyrene latex standards can be reduced approximately by hal

Effect of grain size and temperature on
✍ F.R. Stonesifer 📂 Article 📅 1978 🏛 Elsevier Science 🌐 English ⚖ 882 KB

Crack growth-rate tests were performed in a medium-strength pressure vessel steel, AS33 B, which had been annealed to produce materials with widely varying priqr austenite grain sizes, Testing was at two temperatures, normal room temperature and liquid nitrogen temperature, both on the lower shelf o