## Abstract In clinical outcome studies, small component sizes, female gender, femoral shape, focal bone defects, bad bone quality, and biomechanics have been associated with failures of resurfacing arthroplasties. We used a well‐established experimental setup and human bone specimens to analyze th
Effects of material properties of femoral hip components on bone remodeling
✍ Scribed by Dr. Harrie Weinans; Rik Huiskes; Henk J. Grootenboer
- Publisher
- Elsevier Science
- Year
- 1992
- Tongue
- English
- Weight
- 902 KB
- Volume
- 10
- Category
- Article
- ISSN
- 0736-0266
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Bone loss around femoral hip stems is one of the problems threatening the long‐term fixation of uncemented stems. Many believe that this phenomenon is caused by reduced stresses in the bone (stress shielding). In the present study the mechanical consequences of different femoral stem materials were investigated using adaptive bone remodeling theory in combination with the finite element method. Bone‐remodeling in the femur around the implant and interface stresses between bone and implant were investigated for fully bonded femoral stems. Cemented stems (cobalt‐chrome or titanium alloy) caused less bone resorption and lower interface stresses than uncemented stems made from the same materials. The range of the bone resorption predicted in the simulation models was from 23% in the proximal medial cortex surrounding the cemented titanium alloy stem to 76% in the proximal medial cortex around the uncemented cobalt‐chrome stem. Very little bone resorption was predicted around a flexible, uncemented “iso‐elastic” stem, but the proximal interface stresses increased drastically relative to the stiffer uncemented stems composed of cobalt‐chrome or titanium alloy. However, the proximal interface stress peak was reduced and shifted during the adaptive remodeling process. The latter was found particularly in the stiffer uncemented cobalt‐chrome‐molybdenum implant and less for the flexible isoelastic implant.
📜 SIMILAR VOLUMES
## Abstract Chondroitin sulphate (CS) has an anti‐inflammatory effect and increases the regeneration ability of injured bone. The goal of this study was to characterize the material properties and osteoconductive potency of calcium phosphate bone cements modified with CS. The early interface reacti
## Abstract Bone loss in the proximal femur at the time of revision hip arthroplasty for a failed primary cemented femoral component can substantially reduce the stability of the revision stem, Use of an extended‐length femoral component has been suggested to aid in achieving long‐term fixation; ho
## Abstract The ROBODOC system has provided better fit and fill of the stem and less destruction of the bony architecture than with manual surgery. These benefits might affect femoral periprosthetic bone remodeling. We evaluated the effects of robotic milling in cementless total hip arthroplasty (T
## Abstract A quantitative assessment of cross‐sectional cortical bone remodeling in the femoral diaphysis following hip arthroplasty was made by direct in vitro measurements of cross‐sectional geometric properties. We obtained eight femora from four female cadavers ranging in age from 77 to 96 yea