Cod liver oil (CLO) is known to contain a complex mixture of triacylglycerols (TAGs) in which the component fatty acids include: myristic (C(14:0), M), C(14:1) (M(1)), palmitic (C(16:0), P), palmitoleic (C(16:1), P(1)), stearic (C(18:0), S), oleic (C(18:1), O), linoleic (C(18:2), L), arachidic (C(20
Effect of Structure on the Signal Strength of Oligosaccharides in Matrix-assisted Laser Desorption/Ionization Mass Spectrometry on Time-of-flight and Magnetic Sector Instruments
โ Scribed by T. J. P. Naven; D. J. Harvey
- Publisher
- John Wiley and Sons
- Year
- 1996
- Tongue
- English
- Weight
- 501 KB
- Volume
- 10
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
โฆ Synopsis
The signal strength of the MNa' ion from 25 underivatized oligosaccharides (linear, and both 0-and N-linked oligosaccharides from glycoproteins) was measured by matrix-assisted laser desorption/ionization mass spectrometry on a time-of-flight and on a magnetic sector instrument with 2,s-dihydroxybenzoic acid as the matrix, in order to examine the influence of structure on ion abundance. Oligosaccharides with masses greater than about 1000 Da exhibited similar signal strengths, irrespective of structure, when examined on the time-offlight instrument. Oligosaccharides with masses below loo0 Da displayed a progressive reduction in signal intensity with decreasing molecular weight, an effect which was probably due to temporary saturation of the detector by the intense matrix ions (m/z 130-200 region). Similar studies performed on a magnetic sector instrument revealed that all oligosaccharides studied produced signals of equivalent intensity and that no reduction in signal strength occurred with the smaller sugars. The compounds could be measured with a precision of f 5% on this instrument. The nature of the matrix did not appear to exert a differential effect on the ionization of sugars of different structural types although some matrices appeared to have a preference for ionization of smaller molecules.
๐ SIMILAR VOLUMES
Structural analyses of oligosaccharide-malononitrile derivatives were conducted by matrix-assisted laser desorption/ionization post-source decay (MALDI-PSD) analysis in positive ion mode, and by electrospray ionization collision-induced dissociation (ESI-CID) analysis in negative ion mode. The malon
Matrix-assisted laser desorption/ionization (MALDI) mass spectra were obtained from single biological aerosol particles using an aerosol time-of-flight mass spectrometer (ATOFMS). The inlet to the ATOFMS was coupled with an evaporation/condensation flow cell that allowed the aerosol to be coated wit
The effects of methanol, ethanol, propan-2-01 and acetonitrile on the aerosol matrix-assisted laser desorptionlionization (MALDI) ion signal of hradykinin, bovine insulin and myoglobin were examined. The effect of these solvents mixed with water was also studied. The aerosol MALDI ion signal for eac
This paper describes experiments carried out within the framework of examining capabilities of MALDI-TOF-MS in the characterisation of fossil fuels and related materials. The work has focused on the effect of interactions between sample structure and matrix composition on the quality of MALDI spectr