𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Effect of Selector Coverage and Mobile Phase Composition on Enantiomeric Separations with Ristocetin A Chiral Stationary Phases

✍ Scribed by K.Helen Ekborg-Ott; Xiande Wang; Daniel W. Armstrong


Publisher
Elsevier Science
Year
1999
Tongue
English
Weight
265 KB
Volume
62
Category
Article
ISSN
0026-265X

No coin nor oath required. For personal study only.

✦ Synopsis


Three different amounts (i.e., selector coverages) of ristocetin A macrocyclic antibiotic have been covalently bonded to silica gel, packed in stainless steel columns, and evaluated as chiral stationary phases (CSPs) in high-performance liquid chromatography (HPLC). The three columns (i.e., CSPs) were examined and compared in the reversed-phase, polar-organic, and normal-phase modes. The retention behavior (kЈ), selectivity (␣), resolution (R S ), and number of theoretical plates (N) for all three columns are discussed and compared in each mobile phase mode. The coverage of the chiral selector had a profound effect on the chromatographic behavior of the more retained enantiomers. A special mobile phase composition (i.e., methanol plus very small amounts of acid and base modifiers) resulted in improved baseline separations, without greatly affecting the analysis times, for all chiral analytes evaluated. The column stabilities were excellent when switching between different mobile phase modes.


πŸ“œ SIMILAR VOLUMES


Effects of solvent on chiral and enantio
✍ Hong-Xun Guo; Steven Wu; Kelly Nadeau; George A. Moniz; Sebastian Caille πŸ“‚ Article πŸ“… 2010 πŸ› John Wiley and Sons 🌐 English βš– 218 KB πŸ‘ 1 views

## Abstract The separation of R,R‐, S,S‐, and meso‐Koga bases on derivatized amylose chiral stationary phases (CSP) has been studied using different alcohol and alcohol‐hexane mixtures as eluant. Straight‐chain and branched alcohols with carbon numbers from one to four were investigated. The carbon

Effect of mobile-phase composition on pr
✍ Moira C. Ringo; Christine E. Evans πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 131 KB πŸ‘ 2 views

Modest pressure -350 bars has a significant impact on reversed-phase liquid chromatographic retention using ␀-cyclodextrin stationary phase. Demonstrated here for separations of the positional isomers of nitrophenol and naphthol as well as the enantiomers of hexobarbital and mephobarbital, the effec

Enantioselective separation of enantiome
✍ Tristan D. Booth; W. John Lough; Mansoor Saeed; Terrence A.G. Noctor; Irving W. πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 167 KB πŸ‘ 2 views

A series of enantiomeric amides have been chromatographed on three amylose-based chiral stationary phases (CSPs): amylose tris(3,5-dimethylphenylcarbamate) (AD-CSP), amylose tris(S-phenylethylcarbamate) (AS-CSP), and amylose tris(Rphenylethyl-carbamate) (AR-CSP). The relative retentions and enantios