𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Effect of fin spacing on the heat transfer and pressure drop of a two-row plate fin and tube heat exchanger

✍ Scribed by Z.Q. Chen; J.X. Ren


Publisher
Elsevier Science
Year
1988
Tongue
English
Weight
902 KB
Volume
11
Category
Article
ISSN
0140-7007

No coin nor oath required. For personal study only.


πŸ“œ SIMILAR VOLUMES


The heat transfer and pressure drop char
✍ Kiyoshi Kawaguchi; Kenichi Okui; Toshihiro Asai; Yutaka Hasegawa πŸ“‚ Article πŸ“… 2006 πŸ› John Wiley and Sons 🌐 English βš– 701 KB

## Abstract In recent years the requirement for the reduction of energy consumption has been increasing to solve the problems of global warming and the shortage of petroleum resources. For example, in the power generation field, as thermal power generation occupies 60% of the power generation deman

The heat transfer and pressure drop char
✍ Kiyoshi Kawaguchi; Kenichi Okui; Toshihiro Asai; Yutaka Hasegawa πŸ“‚ Article πŸ“… 2006 πŸ› John Wiley and Sons 🌐 English βš– 829 KB

## Abstract In recent years the requirement for the reduction of energy consumption has been increasing to solve the problems of global warming and the shortage of petroleum resources. For example, in the power generation field, as thermal power generation occupied 60% of the power generation deman

Convective heat transfer and pressure dr
✍ Feng Wu; Mei Lin; Lin Tian; Qiuwang Wang; Laiqin Luo πŸ“‚ Article πŸ“… 2007 πŸ› John Wiley and Sons 🌐 English βš– 784 KB

## Abstract The fluid flows and heat transfer characteristics of a tube with internal longitudinal fins were investigated experimentally and numerically. The realizable turbulence model was adopted to simulate the problem, whose results indicate a good agreement with the measured data. Compared wit

Convective heat transfer and pressure dr
✍ Lin Tian; Qiuwang Wang; Gongnan Xie; Cunlu Zhao; Laiqin Luo πŸ“‚ Article πŸ“… 2007 πŸ› John Wiley and Sons 🌐 English βš– 416 KB

## Abstract Pressure drop and heat transfer characteristics of air in three annular tubes with different internal longitudinal fins were investigated experimentally at uniform wall heat flux. The tested tubes have a double‐pipe structure with the inner blocked tube as an insertion. Three different

Heat transfer enhancement by using a rec
✍ Gulshan Sachdeva; K.S. Kasana; R. Vasudevan πŸ“‚ Article πŸ“… 2010 πŸ› John Wiley and Sons 🌐 English βš– 607 KB

## Abstract The present numerical analysis pertains to the heat transfer enhancement in a plate‐fin heat exchanger employing triangular shaped fins with a rectangular wing vortex generator on its slant surfaces. The study has been carried out for three different angles of attack of the wing, i.e.,