## Abstract Introduction: In this study we investigated the influence of gender and obesity on electrical current thresholds in an attempt to optimize the application of skeletal muscle electrical stimulation (ES) in clinical practice. Methods: Thirtyβtwo obese and 35 ageβmatched, nonβobese men and
Effect of electric currents on bacterial detachment and inactivation
β Scribed by Seok Hoon Hong; Joonseon Jeong; Soojin Shim; Heekyoung Kang; Sunghoon Kwon; Kyung Hyun Ahn; Jeyong Yoon
- Publisher
- John Wiley and Sons
- Year
- 2008
- Tongue
- English
- Weight
- 456 KB
- Volume
- 100
- Category
- Article
- ISSN
- 0006-3592
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
Since biofilms show strong resistance to conventional disinfectants and antimicrobials, control of initial bacterial adhesion is generally accepted as one of the most effective strategies for preventing biofilm formation. Although electrical methods have been widely studied, the specific properties of cathodic, anodic, and block currents that influence the bacterial detachment and inactivation remained largely unclear. This study investigated the specific role of electric currents in the detachment and inactivation of bacteria adhered to an electrode surface. A realβtime bacterial adhesion observation and control system was employed that consisted of Pseudomonas aeruginosa PAO1 (PAO1) with green fluorescent protein as the indicator microorganism and a flow cell reactor mounted on a fluorescent microscope. The results suggest that the bacteria that remained on the electrode surface after application of a cathodic current were alive, although the extent of detachment was significant. In contrast, when an anodic current was applied, the bacteria that remained on the surface became inactive with time, although bacterial detachment was not significant. Further, under these conditions, active bacterial motions were observed, which weakened the binding between the electrode surface and bacteria. This phenomenon of bacterial motion on the surface can be used to maximize bacterial detachment by manipulation of the shear rate. These findings specific for each application of a cathodic or anodic electric current could successfully explain the effectiveness of block current application in controlling bacterial adhesion. Biotechnol. Bioeng. 2008;100: 379β386. Β© 2007 Wiley Periodicals, Inc.
π SIMILAR VOLUMES
The effects of low frequency pulsed electrical current on epidermal repair in vitro were examined. Chargebalanced current stimuli proposed for chronic wound treatment were tested on skin keratinocytes cultured at an air-liquid interface on dead human dermis. Results imply that the balance between pr
The effects of 50 Hz sinusoidal electric currents and magnetic fields on the Gram-positive skin bacterium Propionibacterium acnes were investigated. Intracellular free calcium ([Ca 2 ] i ), intracellular pH (pH i ), and cell viability were examined, based on their relevance to ELF field studies and
The effects of the drifts have been studied on the high parallel Mach flows near the X-point associated with the divertor plasma detachment. Numerical calculations using a 2D edge plasma simulation code (the SOLPS 5.0 code) have been applied to the analysis of the JT-60U W-shaped divertor plasmas. T