Effect of contrast enhancement on the measurement of carotid arterial lumen and wall volume using MRI
✍ Scribed by Binh An P. Phan; Baocheng Chu; William S. Kerwin; Dongxiang Xu; Chun Yuan; Thomas Hatsukami; Xue-Qiao Zhao
- Publisher
- John Wiley and Sons
- Year
- 2006
- Tongue
- English
- Weight
- 211 KB
- Volume
- 23
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Purpose
To investigate whether gadolinium (Gd)‐based contrast enhancement (CE) affects high‐resolution magnetic resonance imaging (MRI) measurements of carotid arterial wall volume.
Materials and Methods
The common carotid artery (CCA), bifurcation, and internal carotid artery (ICA) of 50 consecutive patients were imaged using 1.5T MRI. T1‐weighted (T1W) images were obtained before and after Gd administration. Pre‐ and post‐CE measurements were compared among different arterial locations of the CCA, bifurcation, and ICA, and among different atherosclerotic lesion types.
Results
In comparison to pre‐CE T1W images, post‐CE images showed an increase in the apparent wall volume measurement of 28.2% (108.7 mm^3^ vs. 84.7 mm^3^, P < 0.001). The post‐CE measurement increases in wall volume for the CCA, bifurcation, and ICA were 26.7%, 29.2%, and 28.0%, respectively.
Conclusion
Gd CE causes a significant increase in the apparent volume of the carotid wall throughout multiple carotid artery locations, which may be associated with improved visibility or neovascularization. J. Magn. Reson. Imaging 2006. © 2006 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract ## Purpose: To determine the effect of cardiac‐related carotid artery motion on the image quality of 3D contrast‐enhanced MR angiography (CEMRA) in patients presenting with suspected carotid artery disease. ## Materials and Methods: Twenty patients with suspected carotid artery disea
## Abstract ## Purpose To evaluate the effect of flip angle on volume flow rate measurements obtained with nontriggered phase‐contrast magnetic resonance imaging (MRI) in vivo. ## Materials and Methods We prospectively measured volume flow rates of the bilateral internal carotid artery and the b
The arterial input function is crucial in pharmacokinetic analysis of dynamic contrast-enhanced MRI data. Among other artifacts in arterial input function quantification, the blood inflow effect and nonideal radiofrequency spoiling can induce large measurement errors with subsequent reduction of acc
## Abstract ## Purpose To determine whether three‐dimensional (3D) contrast‐enhanced MR angiography (CE‐MRA) of carotid artery disease may be more effective when performed at double or triple the spatial resolution of the present common clinical standard at 1.5T. ## Materials and Methods A total