𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Effects of doubling and tripling the spatial resolution in standard 3D contrast-enhanced magnetic resonance angiography of carotid artery disease

✍ Scribed by Brad Hnatiuk; Derek J. Emery; Alan H. Wilman


Publisher
John Wiley and Sons
Year
2007
Tongue
English
Weight
158 KB
Volume
27
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose

To determine whether three‐dimensional (3D) contrast‐enhanced MR angiography (CE‐MRA) of carotid artery disease may be more effective when performed at double or triple the spatial resolution of the present common clinical standard at 1.5T.

Materials and Methods

A total of 110 consecutive patients with suspected carotid artery disease were imaged with elliptical centric 3D CE‐MRA. The total acquisition time was increased from the standard clinical protocol of 21 seconds up to 60 seconds in 10‐second steps, with corresponding voxel volume reductions from 0.95 mm^3^ down to 0.35 mm^3^. Quantitative and blinded qualitative measurements were then performed to determine the preferred imaging time.

Results

In patients with significant stenosis, the 40‐second acquisition with 0.53‐mm^3^ voxels produced significantly sharper images of the carotid bifurcation than the 21‐second standard using 0.95‐mm^3^ voxels, but did not have a significant effect in patients without disease.

Conclusion

In patients with carotid artery stenosis, decreasing the voxel volume to 0.5 mm^3^ by increasing the scan time from 21 to 40 seconds resulted in sharper depiction of the carotid stenosis. Further decreases in voxel volume, by extending the acquisition time further, did not improve the vessel depiction due to both signal‐to‐noise ratio (SNR) and sharpness losses. J. Magn. Reson. Imaging 2007. © 2007 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


High temporal and spatial resolution 3D
📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 36 KB

Blackwell Futura Media Services designates this journal-based CME activity for a maximum of 1 AMA PRA Category 1 Credit TM . Physicians should only claim credit commensurate with the extent of their participation in the activity. Blackwell Futura Media Services is accredited by the Accreditation Co

Low-dose 3D time-resolved magnetic reson
✍ Youn-Joo Lee; Gerhard Laub; So-Lyung Jung; Won-Jong Yoo; Young-Joo Kim; Kook-Jin 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 300 KB 👁 1 views

## Abstract ## Purpose To evaluate the feasibility of low‐dose, 3D time‐resolved contrast‐enhanced magnetic resonance angiography (TR‐CEMRA) in the assessment of the supraaortic vessel, and to compare the results with high‐resolution contrast‐enhanced MRA (HR‐CEMRA). ## Materials and Methods Thi

Direct comparison of sensitivity encodin
✍ R. Muthupillai; E. Douglas; S. Huber; B. Lambert; M. Pereyra; G.J. Wilson; S.D. 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 381 KB 👁 1 views

## Abstract ## Purpose: To assess the effect of attaining higher spatial resolution in contrast‐enhanced magnetic resonance angiography (MRA) of renal arteries using parallel imaging, sensitivity encoding (SENSE), by comparing the SENSE contrast‐enhanced (CE) MRA against a conventional CE‐MRA prot

Dose comparison of single- vs. double-do
✍ C. Jourdan; J.T. Heverhagen; M.V. Knopp 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 344 KB 👁 1 views

## Abstract ## Purpose To compare the intraindividual differences of single‐dose (D~S~) and double‐dose (D~D~) gadolinium diethylenetriamine pentaacetic acid (Gd‐DTPA)‐enhanced magnetic resonance angiography (MRA) in the carotid arterial territory, an open‐label single‐center trial with blinded ev