Effect of anastomosis and geometry of vessel curvature on blood flow velocity and patency in microvessels

✍ Scribed by Wing Yung Cheung; Feng Zhang; Urs Bosch; Harry J. Buncke; William C. Lineaweaver


Publisher
John Wiley and Sons
Year
1996
Tongue
English
Weight
317 KB
Volume
17
Category
Article
ISSN
0738-1085

No coin nor oath required. For personal study only.

✦ Synopsis


The effect of the geometry of the vessel and the number of anastomoses on the blood flow was studied. Four different shapes of the vessel were constructed by using a 6-cm-long double vein graft model with three anastomoses: (1) an alpha loop, (2) an omega loop, (3) a sigmoid curve, and (4) straight. Blood flow was measured by an ultrasound Doppler flowmeter. The result showed no alternation in blood flow across different geometry and through three patent microanastomoses. However, six out of seven vein grafts were thrombosed at 24 hr postoperative due to vascular kinks. This model demonstrates potential sites of kinking at the dissection end of the femoral artery, the microanastomoses, the side branches of the vein graft, and the adventitial adhesions. This model is recommended to microvascular trainees for the study of kinking and the management of redundant pedicles and vein grafting.


πŸ“œ SIMILAR VOLUMES


A literature review: The effects of magn
✍ Julia C. McKay; Frank S. Prato; Alex W. Thomas πŸ“‚ Article πŸ“… 2007 πŸ› John Wiley and Sons 🌐 English βš– 155 KB πŸ‘ 2 views

## Abstract The effect of magnetic field (MF) exposure on microcirculation and microvasculature is not clear or widely explored. In the limited body of data that exists, there are contradictions as to the effects of MFs on blood perfusion and pressure. Approximately half of the cited studies indica

Analysis of vessel wall morphology, bloo
✍ Haude, Michael ;Altmann, Christoph ;Eick, Beate ;Liu, Fengqi ;Schwippert, Barbar πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 271 KB πŸ‘ 2 views

A patient with AMI caused by a large thrombus in the proximal LAD was successfully treated with PTCA and an intracoronary lysis combined with the platelet-receptor antagonist c7E3. Analysis of cellular hemostasis after 1 and 6 months revealed a sustained platelet activation despite combined anti-pla

Umbilical artery catheters and blood flo
✍ Shah, Jayesh B.; Bracero, Luis A.; Gewitz, Michael H.; Fish, Bernard G.; Dweck, πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 36 KB πŸ‘ 1 views

Purpose. We studied whether umbilical artery catheters (UACs) affect blood flow in the superior mesenteric artery (SMA) of neonates. Methods. Noninvasive duplex pulsed Doppler sonography was used to measure peak systolic velocity, end-diastolic velocity, and mean flow velocity in the SMA. The resis