ECG-optimized phase contrast line-scanned MR angiography

✍ Scribed by F. R. Korosec; C. A. Mistretta; P. A. Turski


Publisher
John Wiley and Sons
Year
1992
Tongue
English
Weight
936 KB
Volume
24
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

We describe a rapid phase contrast line scan MR angiographic imaging technique. A projection angiogram is obtained by sequentially imaging a series of thin slices oriented perpendicular to the primary flow direction. Bipolar gradient subtraction is employed to suppress signal from static tissues, which in turn allows elimination of phase encoding in the depth dimension. The sequence is cardiac gated to improve image quality and to allow observation of hemodynamics. To further improve image quality, the amplitude of the bipolar gradient is altered throughout the cardiac cycle to provide maximum vessel signal at all cardiac phases. The ECG‐gated phase contrast line scan sequence has been used to image regions where cardiac pulsatility and respiratory motion compromise the quality of images obtained using standard spin warp angiographic methods. © 1992 Academic Press, Inc.


📜 SIMILAR VOLUMES


High-speed line scan MR angiography
✍ Donna G. Brown; Stephen J. Riederer; Ronald C. Wright; Yu Liu; Farhad Farzaneh 📂 Article 📅 1990 🏛 John Wiley and Sons 🌐 English ⚖ 460 KB

## Abstract We describe a system which forms MR angiographic images at high speed. Multiple axial sections are imaged sequentially using a 2DFT GRASS sequence with TR/TE 50/15 ms, 64 phase encodings per image. Reconstruction and projection of each image are performed immediately (within 220 ms) aft

Enhancement of phase-contrast MR angiogr
✍ Akihiro Tanimoto; Yuji Yuasa; Kyoichi Hiramatsu 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 580 KB

## Abstract The effect of superparamagnetic iron oxide particles (AMI‐227) was assessed in three‐dimensional (3D) phase‐contrast (PC) MR angiography (MRA), with various scanning parameters for rats at 1.5 T. The blood T1 and T2 before and after 20 μmol Fe/kg of AMI‐227 injection were measured seque

Orthogonal measurement of thoracic aorta
✍ William R. Bireley II; Lincoln O. Diniz; Elliott M. Groves; Karin Dill; Timothy 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 406 KB

## Abstract ## Purpose To compare orthogonal measurements of the thoracic aortic luminal diameter to standard axial measurements within the same patient population using ECG‐gated high‐resolution contrast‐enhanced MR angiography (CE‐MRA). ## Materials and Methods In all, 45 consecutive patients