𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Dynamic simulation of first pass myocardial perfusion MR with a novel perfusion phantom

✍ Scribed by Amedeo Chiribiri; Andreas Schuster; Masaki Ishida; Gilion Hautvast; Niloufar Z Nooralipour; Matthias Paul; Shazia Hussain; Philip Batchelor; Marcel Breeuwer; Tobias Schaeffter; Eike Nagel


Publisher
BioMed Central
Year
2011
Tongue
English
Weight
501 KB
Volume
13
Category
Article
ISSN
1097-6647

No coin nor oath required. For personal study only.

✦ Synopsis


To describe a novel hardware MR-perfusion phantom to model first-pass of a bolus of contrast in the cardiac cavities and large thoracic vessels (arterial input function, AIF) and in the myocardium, allowing for the acquisition of dynamic first-pass MR-perfusion data and for a precise control of cardiac output and myocardial perfusion for true validation of perfusion quantification.


📜 SIMILAR VOLUMES


Fast mapping of myocardial blood flow wi
✍ Thomas A. Goldstein; Michael Jerosch-Herold; Bernd Misselwitz; Haosen Zhang; Rob 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 318 KB

## Abstract Accurate and fast quantification of myocardial blood flow (MBF) with MR first‐pass perfusion imaging techniques on a pixel‐by‐pixel basis remains difficult due to relatively long calculation times and noise‐sensitive algorithms. In this study, Zierler's central volume principle was used

Multislice MR first-pass myocardial perf
✍ Martin H.K. Hoffmann; Florian T. Schmid; Martin Jeltsch; Arthur Wunderlich; Jeff 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 441 KB

## Abstract ## Purpose To compare a new 12‐element body phased‐array coil with a conventional four‐element surface receiver coil array to provide increased signal‐to‐noise ratios (SNRs) for cardiac steady state free precession (SSFP) perfusion imaging. ## Materials and Methods Thirteen consecuti

First-pass contrast-enhanced myocardial
✍ Marcus Makowski; Christian Jansen; Ian Webb; Amedeo Chiribiri; Eike Nagel; Rene 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 345 KB

First-pass contrast-enhanced myocardial perfusion MRI in rodents has so far not been possible due to the temporal and spatial resolution requirements. We developed a new first-pass perfusion MR method for rodent imaging on a clinical 3.0-T scanner (Philips Healthcare, Best, The Netherlands) that emp

Nonlinear myocardial signal intensity co
✍ Li-Yueh Hsu; Peter Kellman; Andrew E Arai 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 609 KB

## Abstract ## Purpose To study the nonlinearity of myocardial signal intensity and gadolinium contrast concentration during first‐pass perfusion MRI, and to compare quantitative perfusion estimates using nonlinear myocardial signal intensity correction. ## Materials and Methods The nonlinearity