## Abstract Accurate and fast quantification of myocardial blood flow (MBF) with MR first‐pass perfusion imaging techniques on a pixel‐by‐pixel basis remains difficult due to relatively long calculation times and noise‐sensitive algorithms. In this study, Zierler's central volume principle was used
Multislice MR first-pass myocardial perfusion imaging: Impact of the receiver coil array
✍ Scribed by Martin H.K. Hoffmann; Florian T. Schmid; Martin Jeltsch; Arthur Wunderlich; Jeffrey L. Duerk; Bernd Schmitz; Andrik J. Aschoff
- Publisher
- John Wiley and Sons
- Year
- 2005
- Tongue
- English
- Weight
- 441 KB
- Volume
- 21
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Purpose
To compare a new 12‐element body phased‐array coil with a conventional four‐element surface receiver coil array to provide increased signal‐to‐noise ratios (SNRs) for cardiac steady state free precession (SSFP) perfusion imaging.
Materials and Methods
Thirteen consecutive patients were included in the study. Patients were examined both with a four‐element surface coil array and a 12‐element body coil array. First‐pass myocardial perfusion imaging using saturation recovery SSFP was acquired during antecubital injection of Gd‐DTPA. Imaging parameters: TR 2.8 msec/TE 1.3 msec, flip angle 50°, bandwidth 960 Hz/pixel and half‐Fourier acquisition. SNR was calculated using six regions of interest (ROI) for the myocardial perfusion scans. Calculations of corresponding ROIs using the two different coil setups were compared using analysis of variance (ANOVA). Semiquantitative perfusion parameters were calculated for both groups.
Results
The mean SNR in myocardial perfusion imaging increased by 21% using the 12‐element coil setup (P < 0.001) when compared to the four‐element coil. ROI comparisons revealed an increased signal inhomogeneity with the 12‐element coil when compared to four‐element coil experiments. Absolute normal range values of semiquantitative perfusion parameters were consistently higher using the 12‐element coil setup (P < 0.001).
Conclusion
The 12‐element coil array provides higher SNR, but these improvements come with trade‐offs in image homogeneity. Increased SNR translates into higher semiquantitative perfusion values and offers the potential for improved detection of perfusion defects. J. Magn. Reson. Imaging 2005;21:310–316. © 2005 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract ## Purpose: To test whether image normalization using either a separate 3D proton‐density (PD)‐weighted prescan, or 2D PD‐weighted images prior to the perfusion series, improves correction of differences in spatial sensitivity induced by radiofrequency (RF) surface receiver coils. Orig
## Abstract ## Purpose To compare signal‐to‐noise ratio (SNR), contrast‐to‐noise (CNR) ratio, and diagnostic accuracy of a newly developed saturation recovery (SR)‐TrueFISP‐two‐dimensional (2D) sequence with an SR‐TurboFLASH‐2D sequence. ## Materials and Methods In seven healthy subjects and nin
The purpose of this study was to correlate the abnormal signal area on various magnetic resonance (MR) images to the infarct area on pathologic examination and to assess the myocardial viability on the basis of MR images. T2weighted, first-pass perfusion, and delayed gadolinium-enhanced T1-weighted