## Abstract ## __Background.__ The additional value of single photon emission computed tomography with CT (SPECT/CT) for detection and localization of sentinel nodes in patients with a melanoma of the head and neck was determined. ## __Methods.__ Thirtyβeight patients received conventional lymph
Dynamic MR lymphangiography and carbon dye for sentinel lymph node detection: A solution for sentinel lymph node biopsy in mucosal head and neck cancer
β Scribed by Richard W. Nason; Mark G. Torchia; Carmen M. Morales; James Thliveris
- Publisher
- John Wiley and Sons
- Year
- 2005
- Tongue
- English
- Weight
- 232 KB
- Volume
- 27
- Category
- Article
- ISSN
- 1043-3074
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
Background.
The practical application of sentinel lymph node biopsy in squamous cell carcinoma of the head and neck is restricted by the time sensitivity of blue dye and lack of spatial resolution and nonspecific node enhancement with radiocolloid. This study evaluates the use of magnetic resonance (MR) lymphangiography and carbon dye labeling to circumvent these limitations.
Methods.
Gadomer/carbon dye mixture was injected into the tongue and stifle of adult swine (n = 4). MR lymphatic mapping was followed by intraoperative mapping with isosulfan blue dye. Sentinel lymph node biopsy and completion node dissection were performed 60 minutes after injection in four nodal basins and at 7 days after injection in eight.
Results.
The technique was successful in all 12 nodal basins. The sentinel lymph nodes were stained black at the time of the immediate and delayed dissections.
Conclusions.
MR lymphangiography provides temporal and anatomic localization of the sentinel lymph node with a single investigation. Carbon dye is a sensitive and persistent visual marker of MRIβtargeted sentinel lymph nodes. Β© 2005 Wiley Periodicals, Inc. Head Neck 27: XXXβXXX, 2005
π SIMILAR VOLUMES
Background and Objectives: To determine the sentinel node detection rate and the accuracy with which the sentinel node histology reflects that of the axilla in a series of patients with palpable invasive breast cancer. Methods: Forty-four patients with clinically node-negative palpable invasive T1 o