Most of the scanning force microscopy (SFM) images of supercoiled DNA on untreated mica thus far reported have not shown tight plectonemic structure seen by electron microscopy, but instead less coiled molecules and sometimes a partly "condensed" state with intimate chain-chain interactions. By obse
Dynamic imaging of structural changes in silver catalysts by environmental scanning electron microscopy
β Scribed by Uwins, Philippa J.R.; Millar, Graeme J.; Nelson, Megan L.
- Publisher
- John Wiley and Sons
- Year
- 1997
- Tongue
- English
- Weight
- 656 KB
- Volume
- 36
- Category
- Article
- ISSN
- 1059-910X
No coin nor oath required. For personal study only.
β¦ Synopsis
Polycrystalline silver catalysts are used extensively for the partial oxidation of methanol to formaldehyde, which is then primarily incorporated in the synthesis process for adhesives and resins. In order to maximize formaldehyde production it is essential to gain a comprehensive understanding of the complex microstructural changes which occur in the catalyst during reaction conditions. However, conventional electron microscopic techniques are incapable of imaging catalysts at high temperatures and in the presence of a gaseous atmosphere. Therefore, an environmental scanning electron microscope (ESEM) has been used to image polycrystalline silver catalysts during simulated industrial conditions. The most dramatic effect of heating various catalysts to 700 degrees C in the ESEM chamber was the formation of "pinholes" in the silver surface. These "pinholes" occur at specific temperatures and are inherently associated with the catalytic process, resulting from near-surface explosions caused by subsurface hydroxyl recombination. Of particular interest was the nature and location of the holes, which preferentially occur in the vicinity of surface defects such as platelets and edge structures. To the best of our knowledge, this study represents the first time that the progress of a catalytic reaction has been observed under in situ conditions by scanning electron microscopy.
π SIMILAR VOLUMES
While image quality from instruments such as electron microscopes, light microscopes, and confocal laser scanning microscopes is mostly influenced by the alignment of optical train components, the atomic force microscope differs in that image quality is highly dependent upon a consumable component,
## Abstract Keratinization or mucification of the epithelium of the rat vagina is related to the hormonal state of the animal. During the normal cycle and after the administration of exogenous hormones (estrogen and progestin) to spayed animals, the surface characteristics and topography of the vag